Wheaton UniSpense ELITE Скачать руководство пользователя страница 3

WHEATON UniSpense

®

 PRO Peristaltic Pump 

 

 

 

 

 

WHEATON  | 800.225.1437 (U.S. & Canada Only) | 856.825.1100 | www.wheatonsci.com| P/N 50099073 Rev. 2/2/10 Lit. No.8734 

 

 
 
UniSpense® PRO Parts Lists and Illustrations 

 

FIG A 

 

Major Component Identification 

FIG B 

 

Lower Housing Assembly 

FIG C 

 

Upper Housing Assembly 

FIG D 

 

Complete Assembly 

FIG E 

 

Wiring Diagram 

FIG F 

 

Remote Footswitch Connector and Pin Outs 

1.0 Limited Warranty

 

All  goods  and  materials  shall  conform  to  WHEATON  Industries  Inc.  specifications  at  the  time  of 
shipment from our plant. WHEATON Industries warrants this product to be free from defects in material 
and  workmanship  for  a  period  of  365  days  from  the  date  of  shipment.  If  the  repair  or  adjustment  is 
necessary  within the  warranty  period  and has  not been the result of mishandling or abuse, WHEATON 
will  either  correct  the  non-conforming  condition,  or  replace  any  nonconforming  goods  or  materials  or 
issue  a  credit  in  the  amount  of  the  purchase  price  paid  and  received  for  such  goods.  All  claims  for 
product  nonconformity  must  be  made  within  ten  (10)  days  of  identifying  such  a  problem  by  calling 
Customer  Service  at  800.225.1437  (U.S.,  Puerto  Rico  and  Canada);  or  Internationally  at  856.825.1100 
and  then  providing  the  Model,  Serial  and  Catalog  Number  of  the  product.  Items  returned  are  to  be 
packed  very  carefully  so  as  to  prevent  damage  in  transit.  WHEATON  will  also  repair  or  adjust  any 
product that is beyond the warranty period for a nominal fee.   

 

WHEATON  makes  no  other  express  or  implied  warranty,  statutory  or  otherwise,  concerning 
materials  or  goods  supplied,  including  without  limitation,  ANY  WARRANTY  of  fitness  for  a 
particular  purpose  or  any  warranty  of  merchantability.  The  warranties  given  are  exclusive  of  all 
other warranties expressed or implied. WHEATON shall not be liable for consequential, special or 
incidental damages. 

 

To expedite any technical or service request, please have the following information available.   
Thank you.  
 

Model:   

Serial #:   

Catalog #:   

 

2.0 Safety Symbols Used in this Manual and On This Product 

 

 

WARNING

  symbol  indicates  attention  to  an  operation  which  can  cause  operator  injury, 

improper function of or damage to the equipment and possible problems with the process. 

 

 
An 

ELECTRICAL DANGER

 symbol  indicates  attention to an operation  which could cause 

electrocution or severe injury. 
 

Содержание UniSpense ELITE

Страница 1: ...heatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 Catalog Numbers W375040 A and W375040 B 100 120V and W375040 C through W375040 J 220 240V WHEATON UniSpense PRO Peristaltic Pump Instruction Manual In...

Страница 2: ...tch Operation and Connector Functions 7 6 Flexible Tubing Holder 8 0 Unit Setup 8 1 Language Selection 8 2 Buzzer Function 8 3 Unit Reset 9 0 Preparing for Batch and Single Dose Dispensing 10 0 Making...

Страница 3: ...s of identifying such a problem by calling Customer Service at 800 225 1437 U S Puerto Rico and Canada or Internationally at 856 825 1100 and then providing the Model Serial and Catalog Number of the...

Страница 4: ...ain long hair 6 Wear safety goggles Wear safety goggles at all times Everyday eyeglasses only have impact resistant lenses they are NOT safety glasses 7 Don t Overreach Keep proper footing and balance...

Страница 5: ...te Ranges For Various Tubing Sizes 3 2 0mm ID 0 5 mL sec and 1 0 mL sec 3 0mm ID 1 0 mL sec and 2 0 mL sec 6 0mm ID 3 5 mL sec and 7 1 mL sec 8 0mm ID 5 6 mL sec and 11 2 mL sec Vertical Head Height A...

Страница 6: ...hed Retain packaging until all parts and unit functionality are confirmed Components Supplied UniSpense PRO peristaltic pump Pump Head Line Cord supplied to fit your local electrical outlet specificat...

Страница 7: ...e selected set ups can be stored in memory and quickly retrieved for later use Selections stored in memory are preserved even after powering the unit down Pump speed is selectable at 75 and 150 RPM A...

Страница 8: ...kinks CAUTION Improper adjustment of the tubing clamps may result in improper performance of tubing or premature wear and failure of tubing DOUBLE CHECK clamp settings before proceeding To Remove Pump...

Страница 9: ...pad Functions and Icons Icons on the right of each screen show the user which keys will be active during function and setup navigation A brief explanation of active keys is listed Help Pushing the hel...

Страница 10: ...or a Pump Running Pump Stopped indicator Pins 1 footswitch and 2 footswitch GND are 5V TTL compatible inputs with pull up resistors and can be driven by an isolated open collector device or dry contac...

Страница 11: ...ispense alert Turning the buzzer function OFF shown will disable the buzzer during the dispense cycle 8 3 Unit Reset Press the UP and DOWN and the LEFT and RIGHT keys to access the Unit Reset Function...

Страница 12: ...ate to the CALIBRATE screen 10 1 Setting Operating Speed Use the LEFT and RIGHT buttons to select the calibration speed Set the Calibration Speed so that the pump runs for at least 15 seconds during t...

Страница 13: ...e Use the UP and DOWN button to navigate the Calibration Dispense icon Prepare to measure a dispense by using a graduated cylinder electronic scale or other device that can accurately measure volume P...

Страница 14: ...nd DOWN and the LEFT and RIGHT keys to enter the batch count Press OK when done Entering 1 will provide a single dispense 11 2 Volume per Dispense Use the UP and DOWN keys to navigate to the Volume pe...

Страница 15: ...and RIGHT keys to enter the dispense volume Press OK when done Press the Start Stop button to resume batch dispensing 11 6 To Run Additional Batches with the Same Settings Press the Start Stop button...

Страница 16: ...storage of parameters If parameters are stored in a register already containing data the old data will be overwritten with the new parameters 12 2 To Recall a Parameter Press the UP and DOWN and the...

Страница 17: ...n of the tubing assembly for excessive wear and leaks Many service problems can often be cured by simply replacing a worn tubing assembly To insure high accuracy the pump rotor and tubing clamping mec...

Страница 18: ...pump motor speed as required Cause Motor control board defective Remedy Replace defective board Cause START Key not pressed Remedy See Unit Features and Component Identification for keypad and displa...

Страница 19: ...Thickness mismatch with pump head used Remedy Tubing wall weight should match pump head specifications Inaccurate Volume Delivery Cause Tubing assembly worn Remedy Replace tubing assembly Cause Pump...

Страница 20: ...IS DISCONNECTED FROM THE AC POWER SOURCE 1 Disconnect the cord set from the AC power source 2 Remove the fuse drawer by using a small flat screwdriver to lift the tab 3 Replace with new fuses 108 120...

Страница 21: ...p WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 21 FIGURE A Major Component Identification Display Screen Keypad Pump Head I O Interface Conn...

Страница 22: ...STAR 6 INT TOOTH 17 1 50099063 STF 6 32 X 1 4 ALUMINUM 18 2 WI056864 FUSE 5X20MM 2 0AT 250V 120V 18 2 WI056862 FUSE 5X20MM 1 0AT 250V FIGURES C THRU E Upper Housing Assembly Main Assembly and Wiring D...

Страница 23: ...WHEATON UniSpense PRO Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 23...

Страница 24: ...WHEATON UniSpense PRO Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 24...

Страница 25: ...WHEATON UniSpense PRO Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 25...

Страница 26: ...WHEATON UniSpense PRO Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 26...

Страница 27: ...WHEATON UniSpense PRO Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 27...

Страница 28: ...arations of Conformity and WEEE Statement WEEE STATEMENT This UniSpense PRO peristaltic pump is not to be discarded in typical trash outlets This unit is to be discarded according to WEEE guidelines e...

Страница 29: ...quirements specified by the appropriate EU Directive with respect to the design and construction of the commercialized version This declaration is invalid if modifications are performed on the device...

Отзывы: