Manual AMP 4200
Valid for
111-425-04-001-00
Version (modifications reseverd)
21.02.2022
Seite 5 of 17
10.1.2. Configuration in the network
The AMP 4200 is delivered with DHCP. I.e. an IP address is automatically assigned to the device as soon
as it is recognized in the network.
Check the current IP address on the device. (Press on "ADJUST / SET" and turn to the left Device Info)
and enter this in the start bar of the browser:
Example:
My IP address: 172.22.0.139
____________
Default password:
Username:
admin
Password:
admin
This opens the configuration interface.
Note:
If you access the amplifier via a network, you can also enter
http://AMP4200/
in the start bar.
If you have changed the user name / password in a previous configuration setting, please enter this
My login details:
User name: _______________________
Password: _______________________
IP address: _______________________
10.1.2. RESET to factory settings
Simultaneously
press the
"BACK"
button and the
"ADJUST / SET"
rotary button
for more than 5
seconds
. This returns the device to the factory settings.
Note:
A RESET (reset to factory settings)
deletes all settings
and
all saved presets
and
sets all outputs to 4-8
ohms