background image

47xxN Series Time Zone Display 

Operating and Installation Instructions

 

8a - Display Setup 

The 472xN and 474xN series time zone displays can be configured to display time of day, alternating time 
& date and continuous date in a number of different display formats as detailed in the table below. Date 
display only available for righthand location. 
 

Fu Di 

Display Setup 

Function 

Display Type 

Description 

'Up' button 
function 

 

hh:mm 

 

 

 

Display Style 

  

ti 

 

Standard time display. 

Exit to Time 
display 

 

 

gb 

 

Alternating time and date in ddmm format. 

Display hold time 

 

 

us 

 

Alternating time and date in mmdd format. 

Display hold time 

 

 

eu 

 

Alternating time and date in yymm format. 

Display hold time 

 

 

cgb 

 

Continuous date in ddmmyy ddmm  format. 

Exit to Time 
display 

 

 

cus 

 

Continuous date in  mmdd  format. 

Exit to Time 
display 

 

 

ceu 

 

Continuous date in yymm format. 

Exit to Time 
display 

 

 

jday 

 

Continuous day of year. 

Exit to Time 
display 

Display 

hold 

dh 

xx 

 

Number of seconds that clock holds between alternating 
display formats - between 1 and 20 seconds. 

Exit to Time 
display 

 

 

 

 

 

14

 Issue 2.1 

Содержание 47 N Series

Страница 1: ...tup Page 7 6 Network Setup Page 10 7 Synchronisation Setup Page 11 8a Display Setup 472xN and 474xN series Page 14 8b Calendar Setup 470xN and 475xN series Page 15 9 Stopwatch Setup Page 16 10 Externa...

Страница 2: ...ts for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The equipment...

Страница 3: ...bility to operate as a multi range programmable stopwatch using supplied infrared remote control or using an external stopwatch control panel or user supplied voltage free contact closure or switch Si...

Страница 4: ...e performed in accordance with current Building Regulations and the Seventeenth Edition of the IEE Wiring Regulations or equivalent local standard The power supply is fitted with an internal fuse In c...

Страница 5: ...ove next setting Function Location Setting Mode See page 5 1 Press Up to enter Location Setting Mode or press to move to next setting Function Synchronisation Setting Mode See page 6 1 Press Up to ent...

Страница 6: ...ess to increment seconds to set to zero Press Up to set minutes count Minutes Setting Mode Press or to increment or decrement minutes Press Up to set the hours count Complete time setting process deta...

Страница 7: ...gs are accessed from the function menu as detailed in section 3 Each time display can be independently configured to display a different world time The 47xxNIL series units have illuminated location l...

Страница 8: ...Aviv 2 Yes 07 MSK 1 Russia Kaliningrad 3 No 08 UTC 3 CHARLIE AST Iraq Baghdad S Arabia Riyadh 3 No 09 MSK Russia Moscow 4 No 10 IRST IRDT Iran Tehran 3 Yes 11 UTC 4 DELTA GST UAE Dubai Abu Dhabi 4 No...

Страница 9: ...T WGST Greenland West Nuuk 3 Yes 65 PMST PMDT US Pierre Miquelon 3 Yes 66 UYT UYST Uruguay Montevideo 3 Yes 67 UTC 2 5 2 1 2 No 68 UTC 2 OSCAR 2 No 69 UTC 1 NOVEMBER CVT Cape Verdi Praia 1 No 70 AZOT...

Страница 10: ...eway by customers DHCP server User setting of NTP server addresses Exit to Time display dh No Static assignment of IP Subnet and Gateway addresses by user User setting of NTP server addresses Select I...

Страница 11: ...r existing 5200 or 4860 series master clock 482 w482 Time code from existing 5200 4860 or 482D series master clock Zo 1 F w482 time code zone that unit will use for synchronisation DCF DCF77 Radio tim...

Страница 12: ...w DHCP and the Up arrow should be pressed again to return to the time display If clock is to DHCP or Static modes the 4 bytes of the first NTP time server address can be programmed in same manner as d...

Страница 13: ...CF or MSF radio time code when connected to either the 484 02 MSF Radio Receiver or 484 03 DCF Radio Receiver supplied separately as follows Clock configuration 1 Press Menu or Up button to access clo...

Страница 14: ...Display Style ti Standard time display Exit to Time display gb Alternating time and date in ddmm format Display hold time us Alternating time and date in mmdd format Display hold time eu Alternating t...

Страница 15: ...as per language table below Calendar 2 Mode Calendar 2 Mode M2 xx As mode settings for Calendar 1 above Calendar 2 Lang Calendar 2 Language C2 xx Calendar 2 Language as per language table below Calen...

Страница 16: ...grammed start time stop at zero Select hold mode SA 03 Down from pre programmed start time then up from zero Select hold mode SA 04 Down from pre programmed start time automatically restart countdown...

Страница 17: ...settings Exit to time display Tc nt Et Tc nt Display continuous temperature display See 406 documentation for further settings Exit to time display Lo cl Et Lo cl Enable Local Master synchronisation o...

Отзывы: