5.

Do not

screw directly to the hull - must be mounted on a bulkhead or additional mounting board.  

6.

WARNING

: Fire hazard. Wiring must comply with applicable electrical standards and include a 

properly sized fuse or circuit breaker. Improper wiring can cause a fire resulting in injury or death. 
Switch off the power while making connections. Suggested wiring information is given as a guide 
only. For full information, refer to the USCG, ABYC and ISO regulations for marine applications and 
wiring gauges,connectors and fuse protection. 

Qty 1  Saltwater Washdown Pump 

Qty 2

3/4” flexible hose adapters

Qty 1

Strainer

Qty 2

1/2” flexible hose adapters

Qty 1

Nozzle

Qty 2

3/4” BSP adapter

WARNING

: Please note that incorrect installation may invalidate the warranty.

Preparation - Always disconnect power sources before installing.

8.1.

Mounting Instructions

a.

Locate in a dry position with adequate ventilation, no more than 3 metres away from the  tank. In 
normal use. 

NOTE

ensure the pump cannot be submerged or sprayed by water

b.

Pump can be mounted horizontally or vertically (we recommend that the pump head is below motor 
level).

c.

Feet positions are adjustable to allow replacement of other pump types. Use No. 8 stainless steel 
screws to fasten pump to solid surface ensuring the pump is securly supported.

8.2

Electrical Wiring 

a.

Use specified fuse in the circuit, as indicated on motor label.

b.

Connect red wire to positive and black wire to negative - recommended wire size is 2.5mm (AWG 13)

c.

Fit an isolating switch with adequate current rating on the positive side of the supply.

d.

To prevent the pump running continuously turn off at isolating switch when vessel is left unattended 
or water supply has been allowed to empty.

Fig 1

Pump 

fittings

Check pump flow direction (as indicated on pump body) and ensure that the strainer provided is attached to the
pump head inlet.

Ensure that pump installation is thoroughly tested before first use. Once installed run the pump ensuring all air is
removed from the system.

This Whale® Wahdown pump is designed to only require minimal maintenance.

WARNING:

Before servicing pump, turn off pump and drain water from system, ensuring where relevant all seacocks

are closed. Ensure that the pump is disconnected from electrics and plumbing during maintenance. 

Annual Checks - 

Whale advise that the boat's plumbing system is checked annually for leaks and obstructions. Also

a pump electrics check is advisable. 

Optimal Performance - 

Ensure the strainer is clear of debris 

7.

PARTS LIST

8.

INSTALLATION

9.

PLUMBING

10.

INSTRUCTIONS FOR USE

11.

MAINTENANCE

NOTE:

Never

use pipe sealant
or sealing tapes on 
threaded adaptors, as
these may enter the pump
and cause failure.

Содержание WD1815

Страница 1: ...the materials are fully compatible with the liquids to be used 1 This pump must not be mounted below the water line when connected to an intake below the water line 2 Not suitable for pumping flammabl...

Страница 2: ...solid surface ensuring the pump is securly supported 8 2 Electrical Wiring a Use specified fuse in the circuit as indicated on motor label b Connect red wire to positive and black wire to negative re...

Страница 3: ...ctions from tank seacock to inlet of pump are secure any air leaks will prevent prime Water leaking at outlet side of pump Check pipework fittings for leaks and repair Check system drain plugs are clo...

Страница 4: ...NOTES...

Страница 5: ...olts en courant continu Si il est destin tre utilis d autres fins ou avec tout autre liquide il est de la responsabilit de l utilisateur de s assurer que la pompe est adapt e pour l utilisation pr vue...

Страница 6: ...ours d brancher les sources d nergie avant l installation 8 1 Instructions de montage a Install e dans un endroit sec et bien a r Pas plus de 3 m tres partir du r servoir En utilisation normale v rifi...

Страница 7: ...ns partir du r servoir S curisez de l entr e de la pompe la vanne de la coque pour viter les fuites d air De l eau fuit pr s de la sortie de la pompe V rifiez la tuyauterie accessoires pour les fuites...

Страница 8: ...ompe de lavage grande eau est prot g e par le brevet suivant United States brevet US 6 840 745 Canadian brevet 2 380 465 United Kingdom brevet EP GB 1 222 392 French brevet EP FR 1 222 392 German brev...

Страница 9: ...che den Betrieb bei einer Stromversorgung von ausschliesslich 12 V d c oder 24 V d c erm glichen Wenn die Absicht besteht sie f r einen anderen Zweck oder mit anderen Fl ssigkeiten zu verwenden oblieg...

Страница 10: ...inen trockenen Ort mit ausreichend Bel ftung h chstens 3 Meter vom Wasserbeh lter entfernt Stellen Sie sicher dass die Pumpe bei normalem Betrieb nicht unter Wasser getaucht oder von Wasser bespritzt...

Страница 11: ...Sie die Anschl sse Sicherung ist durchgebrannt Ersetzen Sie die Sicherung Verstopfung in der Verrohrung berpr fen Sie die Verrohrung auf Knickstellen Pumpe l uft aber es erscheint kein Wasser Pumpe wi...

Страница 12: ...pr fen Sie ob f r die Stromzufuhr zur Pumpe die korrekte Kabelst rke verwendet wird 2 5mm2 AWG 13 um die volle Spannung zur Pumpe zu leiten berpr fen Sie ob die Batterie nicht entladen ist Verrohrung...

Страница 13: ...lig f r detta 1 Denna pump f r inte monteras under vattenlinjen vid anslutning till ett intag under vattenlinjen 2 Pumpen r inte l mplig f r pumpning av brandfarliga v tskor diesel kemikalier etc 3 De...

Страница 14: ...ring som anges p motorns etikett b Anslut r d kabel till plus och svart kabel till minus Rekommenderad kabelarea r 2 5 mm AWG 13 c Montera en str mbrytare p plus polen d F r att f rhindra att pumpen r...

Страница 15: ...uella l ckor Kontrollera s systemets dr neringstappar r st ngda Pumpen sl r p och av n r kranen r ppen Alltf r h gt mottryck Kontrollera om det finns veck p slangen eller om d r r smuts i filtret Kont...

Страница 16: ...ANTECKNINGAR...

Страница 17: ...guidance purposes only WHALE is a registered trademark of Munster Simms Engineering Limited Bangor Northern Ireland trading as Whale Munster Simms Engineering Ltd 2 Enterprise Road Bangor N Ireland BT...

Отзывы: