![Whale GW0500 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/whale/gw0500/gw0500_manual_967136004.webp)
This Whale® Shower Sump System is designed only to require minimal maintenance.
WARNING
- Before servicing, disconnect power and drain system.
Optimal performance
• Regularly remove motor housing and inspect and clean filter to be sure that it is not being blocked by debris.
Annual Checks
• Whale advises that the boat’s plumbing system
must
be checked at least annually for leaks and obstructions. Also a
pump electrics test is advisable. Ensure that the electric test is completed by a qualified electrician/ technician.
NOTE
- Fully drain system for winterizing.
Whale does not guarantee warranty if the system is not fully drained for winterizing.
Whale®, is a registered trademark of Munster Simms Engineering Limited, Bangor Northern Ireland trading as Whale®.
This product complies with all relevant European directives and standards. Please contact Whale® if further details are
required.
Declaration no.: EU- MSE032-000
We the undersigned:
Name of manufacturer:
Munster Simms Engineering Ltd
Address:
2 Entreprise Road, Bangor, Co Down, BT19 7TA
Country: United
Kingdom
Declare under our sole responsibility that the following apparatus:
Product description:
Grey Waste Sump Box
Model name:
Whale
Product codes:
GW0500(B), GW0950(B) and GW0954(B)
Brand name:
Whale
PROBLEM
POSSIBLE CAUSES
POTENTIAL SOLUTION
Pump runs but does
not pump water / pump
pulses
Hose may have
blockage or airlock
Clear the hose of any blockages and ensure that outlet hose runs
upward to the thru-hull connector, with no dips
Impeller may be
restricted
Remove pump housing from base. Remove debris from chamber and
impeller. Ensure that the impeller is firmly attached to shaft and is not
cracked or broken
Pump does not run
Blown fuse
Ensure electrical connections and fuse are waterproof and have not
loosened
Pump continuously
runs
Dirt on sensor
Wipe sensor clean
Motor speed variation
when running dry
Normal operation
13. PATENTS AND TRADEMARKS
14. DECLARATION OF CONFORMITY, STANDARDS, APPROVALS
12. TROUBLESHOOTING
11. WINTERIZING
10. MAINTENANCE
4
3 Way Terminal
Switch
On - Automatic
Brown wires with
yellow crimp
On - Manual Override
Fuse
Brown and white
wire
Whale®
Sump Box
Black Wire
Battery
Off
Figure 3 - Typical Wiring