(a) If the pump will not run:

• 

Check at least one tap is open

Turn the pump isolation switch off and on again

Check the battery condition

Check the mains isolator switch is on 

Check the pump isolator switch is on

Check the contacts in the plug and socket are clean and making contact

• 

Check wiring connections

• 

Check fuse (see fuse box)

(b) If the pump cycles on/off with all taps and shower closed:

• 

Check for air or water leaks in taps and piping

• 

Check that non return valve in socket is free from grit by pushing a suitable blunt object, for example 

a ballpoint pen into the socket nipple against the non-return valve holding the valve open to dislodge 

trapped grit

Recalibrate the system (see calibration section of the installation section)

(c) If pump motor runs steadily and does not stop after 30-40 seconds:

• 

Check all connections in pipework

Recalibrate the system 

Diagnostic Codes

To aid with troubleshooting the LED on the back of the Watermaster® IC has a number of different flash codes as

described in the table below

Watermaster® IC does not require any additional winterizing. For details of how to drain your water system for 

winterizing please visit www.whalepumps.com/rv

For installation or serviceable parts advice please contact Whale

®

Customer Support:

Tel: +44 (0)28 9127 0531

Fax: +44 (0)28 9146 6421

Email: [email protected]  

www.whalepumps.com

7

10. 

TROUBLE SHOOTING

LED

State

Description

Green

Constant On

Tap open, pump running

Green

Fast Flash (< 1 sec)

In Calibration Mode

Green

200ms blink every 5 sec

Calibrated and ready for use

Green

200ms blink every 10 sec

Un-calibrated

Green

200ms blink every 15 sec

Suspended due to dry run need to turn pump switch on and off

Green

200ms blink every 20 sec

Suspended due to low battery voltage, turn pump switch on/off,

need to charge battery

12. 

SERVICE SUPPORT DETAILS

11. 

WINTERISING

Содержание EP1632

Страница 1: ...uct is designed for use with freshwater If it is intended for use with any other liquid it is the user s responsibility to ensure that the materials are fully compatible with the liquids to be used and that a system of safe working practice is applied to installation use and maintenance SPECIFICATION High Flow Watermaster Pump with Intelligent Control IC EP1632 INSTALLATION USER INSTRUCTIONS Produ...

Страница 2: ...at low battery voltages and in a run dry situation when the water supply runs out This patent applied for Intelligent Control is achieved by a pressure switch turning on the pump when the pressure drops to a low level and the microprocessor turning off the pump at programmed current levels which are set during the one time calibration process This calibration process may have to be repeated if the...

Страница 3: ...ons Fire hazard Wiring must comply with applicable electrical standards and include a properly sized fuse or circuit breaker Improper wiring can cause a fire resulting in injury or death Suggested wiring information is given as a guide only Please note that incorrect installation may invalidate the warranty The Watermaster IC is designed to work in conjunction with a 5 Amp automotive fuse see fuse...

Страница 4: ...t TO CONNECT THE IC CONTROL UNIT BACK OF SOCKET Step 1 Switch off the 12V d c supply at the main panel isolator switch Step 2 Unplug the spade connections on the water inlet socket ensuring that you note the order of wires for reconnection with the Watermaster IC see Fig 1 Fig 2 Step 3 Unscrew and remove the pressure switch adjusting screw and locking nut see Fig 2 Step 4 Remove securing screw see...

Страница 5: ...expelled turn off tap the pump should turn off after approximately 10 seconds TO CALIBRATE THE SYSTEM Step 1 Press and hold the calibration button until the green LED starts to flash after 1 3 seconds Fig 7 Step 2 Open the tap and the pump should start there maybe a short delay Step 3 After approximately 30 seconds turn off the tap Step 4 After approximately 10 seconds the pump should still be run...

Страница 6: ... as per steps above in Section 6 To obtain efficient running and maximum pump life ensure the following There is sufficient water in the container Maximum pumping period is not more than 15 minutes All hose connections are firm and water tight The power supply is adequate low performance could result from a weak battery or reduced voltage due to undersized wiring we recommend wiring should be a mi...

Страница 7: ...connections in pipework Recalibrate the system Diagnostic Codes To aid with troubleshooting the LED on the back of the Watermaster IC has a number of different flash codes as described in the table below Watermaster IC does not require any additional winterizing For details of how to drain your water system for winterizing please visit www whalepumps com rv For installation or serviceable parts ad...

Страница 8: ...ster Simms Engineering Ltd 277 279 Old Belfast Road Belfast BT19 1LT Year mark first applied 2012 Limitations of use For use with EP1612 12V submersible pump only Name and position of person binding the manufacturer or authorized representative Signature Name Stanley McFarland Function Engineering Director Location Munster Simms Engineering Ltd 277 279 Old Belfast Road Northern Ireland BT19 1LT Da...

Страница 9: ...ecifications without prior notice Illustrations are for guidance purposes only Please note that by contacting Whale Support you will be indicating your consent to receiving product updates recall information help guides and appropriate marketing messages from us via post email or telephone unless you indicated an objection to receiving such messages Munster Simms Engineering Ltd Old Belfast Road B...

Отзывы: