background image

If the battery voltage is very low (8.5V-9.5V), the Watermaster® IC is designed to shut down after 

approximately 30 seconds operation to prevent the battery being drained further. Restart the system by 

turning the pump isolation switch off and back on. This can be repeated to provide a limited operating mode 

but the battery should be recharged as soon as possible.

Please note that Watermaster® IC is designed to work with the Whale® Pressure Switched Socket 

ES1001 / ES5001, and with the Whale® High Flow Watermaster® pump kit ONLY, and is not compatible with

other sockets or pump systems

For users with other Whale® or non-Whale® products, their systems may be upgraded to IC by purchase of the

Whale product codes - socket ES1001 / ES5001 and Pump & Watermaster® IC (EP1632).

Contact the technical helpline (Whale® 02891 270531) for additional advice on this product or its installation.

2. 

APPLICATION

3. 

WARNINGS

3

This product is not designed for any other purpose than supplying water to a caravan or other 

recreational vehicle system.

Always disconnect power sources before installing or making connections.

Fire hazard. Wiring must comply with applicable electrical standards and include a properly sized fuse or 

circuit breaker. Improper wiring can cause a fire resulting in injury or death. Suggested wiring information is 

given as a guide only.

Please note that incorrect installation may invalidate the warranty.

The Watermaster® IC is designed to work in conjunction with a 5 Amp automotive fuse (see fuse box for fuse

marked ‘pump’).

There 

must be

access to the back of the socket for a once only calibration, and the socket must not be 

mounted at floor level as cables need to plug in to the bottom of the socket.

Please note that incorrect wiring will result in a blown fuse.

Please note that Watermaster® IC is designed to work in conjunction with the EP1612 Watermaster® High 

Flow 12V d.c. pump and the ES1001 / ES5001 Pressure Switched Socket ONLY and will not operate with 

any other Whale® products.

With all applications it is important that a system of safe working practice is applied to installation, use and 

maintenance.

Please note that the Watermaster® IC controller unit is enclosed to protect the electronics. Opening the unit 

will result in damage and will invalidate warranty.

Do not

use the pump in water temperatures above 40ºC (100ºF).

It is best to stand the pump vertically in the tank.

Содержание EP1632

Страница 1: ...uct is designed for use with freshwater If it is intended for use with any other liquid it is the user s responsibility to ensure that the materials are fully compatible with the liquids to be used and that a system of safe working practice is applied to installation use and maintenance SPECIFICATION High Flow Watermaster Pump with Intelligent Control IC EP1632 INSTALLATION USER INSTRUCTIONS Produ...

Страница 2: ...at low battery voltages and in a run dry situation when the water supply runs out This patent applied for Intelligent Control is achieved by a pressure switch turning on the pump when the pressure drops to a low level and the microprocessor turning off the pump at programmed current levels which are set during the one time calibration process This calibration process may have to be repeated if the...

Страница 3: ...ons Fire hazard Wiring must comply with applicable electrical standards and include a properly sized fuse or circuit breaker Improper wiring can cause a fire resulting in injury or death Suggested wiring information is given as a guide only Please note that incorrect installation may invalidate the warranty The Watermaster IC is designed to work in conjunction with a 5 Amp automotive fuse see fuse...

Страница 4: ...t TO CONNECT THE IC CONTROL UNIT BACK OF SOCKET Step 1 Switch off the 12V d c supply at the main panel isolator switch Step 2 Unplug the spade connections on the water inlet socket ensuring that you note the order of wires for reconnection with the Watermaster IC see Fig 1 Fig 2 Step 3 Unscrew and remove the pressure switch adjusting screw and locking nut see Fig 2 Step 4 Remove securing screw see...

Страница 5: ...expelled turn off tap the pump should turn off after approximately 10 seconds TO CALIBRATE THE SYSTEM Step 1 Press and hold the calibration button until the green LED starts to flash after 1 3 seconds Fig 7 Step 2 Open the tap and the pump should start there maybe a short delay Step 3 After approximately 30 seconds turn off the tap Step 4 After approximately 10 seconds the pump should still be run...

Страница 6: ... as per steps above in Section 6 To obtain efficient running and maximum pump life ensure the following There is sufficient water in the container Maximum pumping period is not more than 15 minutes All hose connections are firm and water tight The power supply is adequate low performance could result from a weak battery or reduced voltage due to undersized wiring we recommend wiring should be a mi...

Страница 7: ...connections in pipework Recalibrate the system Diagnostic Codes To aid with troubleshooting the LED on the back of the Watermaster IC has a number of different flash codes as described in the table below Watermaster IC does not require any additional winterizing For details of how to drain your water system for winterizing please visit www whalepumps com rv For installation or serviceable parts ad...

Страница 8: ...ster Simms Engineering Ltd 277 279 Old Belfast Road Belfast BT19 1LT Year mark first applied 2012 Limitations of use For use with EP1612 12V submersible pump only Name and position of person binding the manufacturer or authorized representative Signature Name Stanley McFarland Function Engineering Director Location Munster Simms Engineering Ltd 277 279 Old Belfast Road Northern Ireland BT19 1LT Da...

Страница 9: ...ecifications without prior notice Illustrations are for guidance purposes only Please note that by contacting Whale Support you will be indicating your consent to receiving product updates recall information help guides and appropriate marketing messages from us via post email or telephone unless you indicated an objection to receiving such messages Munster Simms Engineering Ltd Old Belfast Road B...

Отзывы: