Pump hose can be inserted into groove on plug to keep pump off ground while refilling water container (Fig. 8). The

plug should always be removed before moving the caravan/motorhome.

When removing plug:

Step 1 - Lift the lid to unlock the plug

Step 2 - Pull out plug from socket using hand grip

Step 3 - Shut lid

This IC control unit (located on the back of the socket) is designed to be service free and does not contain 

serviceable parts. Please note that the unit is enclosed to protect the electronics. Opening the unit will result in 

damage, and will invalidate warranty.

For information on service kits, please visit www.whalepumps.com

• 

Note - If at any stage the user experiences less than optimum performance from the Whale® Watermaster® 

IC, recalibrate the system as per steps above in Section 6.

• 

To obtain efficient running and maximum pump life, ensure the following:

• 

There is sufficient water in the container.

• 

Maximum pumping period is not more than 15 minutes.

• 

All hose connections are firm and water tight.

• 

The power supply is adequate - low performance could result from a weak battery or 

reduced voltage due to undersized wiring (we recommend wiring should be a minimum 

thickness of 2.5mm²).

• 

When replenishing the water supply, it is possible to create an air lock in the pump. As a 

result, the pump will run noisily and give no discharge. To remedy, unplug from the socket 

while keeping the pump submerged to dislodge  the air pocket in the pump. Also shaking the 

dual hose gently may dislodge the air pocket in the pump, or switch off pump at main panel, 

open a tap outlet and switch pump on again at the main panel. 

6

Fig. 8 Storing pump plug kit

7. 

INSTRUCTIONS FOR PUMP STORAGE WHEN NOT IN USE

8. 

MAINTENANCE

9. 

HELPFUL HINTS

Содержание EP1632

Страница 1: ...uct is designed for use with freshwater If it is intended for use with any other liquid it is the user s responsibility to ensure that the materials are fully compatible with the liquids to be used and that a system of safe working practice is applied to installation use and maintenance SPECIFICATION High Flow Watermaster Pump with Intelligent Control IC EP1632 INSTALLATION USER INSTRUCTIONS Produ...

Страница 2: ...at low battery voltages and in a run dry situation when the water supply runs out This patent applied for Intelligent Control is achieved by a pressure switch turning on the pump when the pressure drops to a low level and the microprocessor turning off the pump at programmed current levels which are set during the one time calibration process This calibration process may have to be repeated if the...

Страница 3: ...ons Fire hazard Wiring must comply with applicable electrical standards and include a properly sized fuse or circuit breaker Improper wiring can cause a fire resulting in injury or death Suggested wiring information is given as a guide only Please note that incorrect installation may invalidate the warranty The Watermaster IC is designed to work in conjunction with a 5 Amp automotive fuse see fuse...

Страница 4: ...t TO CONNECT THE IC CONTROL UNIT BACK OF SOCKET Step 1 Switch off the 12V d c supply at the main panel isolator switch Step 2 Unplug the spade connections on the water inlet socket ensuring that you note the order of wires for reconnection with the Watermaster IC see Fig 1 Fig 2 Step 3 Unscrew and remove the pressure switch adjusting screw and locking nut see Fig 2 Step 4 Remove securing screw see...

Страница 5: ...expelled turn off tap the pump should turn off after approximately 10 seconds TO CALIBRATE THE SYSTEM Step 1 Press and hold the calibration button until the green LED starts to flash after 1 3 seconds Fig 7 Step 2 Open the tap and the pump should start there maybe a short delay Step 3 After approximately 30 seconds turn off the tap Step 4 After approximately 10 seconds the pump should still be run...

Страница 6: ... as per steps above in Section 6 To obtain efficient running and maximum pump life ensure the following There is sufficient water in the container Maximum pumping period is not more than 15 minutes All hose connections are firm and water tight The power supply is adequate low performance could result from a weak battery or reduced voltage due to undersized wiring we recommend wiring should be a mi...

Страница 7: ...connections in pipework Recalibrate the system Diagnostic Codes To aid with troubleshooting the LED on the back of the Watermaster IC has a number of different flash codes as described in the table below Watermaster IC does not require any additional winterizing For details of how to drain your water system for winterizing please visit www whalepumps com rv For installation or serviceable parts ad...

Страница 8: ...ster Simms Engineering Ltd 277 279 Old Belfast Road Belfast BT19 1LT Year mark first applied 2012 Limitations of use For use with EP1612 12V submersible pump only Name and position of person binding the manufacturer or authorized representative Signature Name Stanley McFarland Function Engineering Director Location Munster Simms Engineering Ltd 277 279 Old Belfast Road Northern Ireland BT19 1LT Da...

Страница 9: ...ecifications without prior notice Illustrations are for guidance purposes only Please note that by contacting Whale Support you will be indicating your consent to receiving product updates recall information help guides and appropriate marketing messages from us via post email or telephone unless you indicated an objection to receiving such messages Munster Simms Engineering Ltd Old Belfast Road B...