Fig 10 Secure pipework
Ensure that pump installation is thoroughly tested before first use.
NOTE
- These are all automatic or semi-automatic applications - ensure that isolator
switch is turned on.
BILGE APPLICATION
Gulper® IC with Strainer IC - Place finger over sensor area to check pump is
activated, remove finger and wait for the pump to stop (45 seconds).
Fig 11 Testing Strainer IC
This Whale Gulper® IC is designed to only require minimal maintenance.
WARNING
: Before servicing pump, turn off pump and drain water from system.
Annual Checks
•
Whale advise that the boat's plumbing system is checked annually for
leaks and obstructions. Also a pump electrics check is advisable.
•
Before inspecting or replacing the diaphragm, disconnect the electrical
supply.
Optimal Performance
•
Ensure this product is clear of debris
IF THE PUMP IS NOT OPERATING AS EXPECTED:-
•
Loosen the hose clips to release the pump from plumbing.
•
Unscrew the Ezi-clamp clamping ring to release the pump head - see Fig
3 - This will release the pump head, and allow easy access to the valves
& diaphragm.
•
The diaphragm and valves should be checked for any excessive wear,
damage or cracks, and should be replaced if necessary (service kit
AK2050 - replacement pump head).
13. INSTRUCTIONS FOR USE
14. MAINTENANCE