11.vi. Wiring Diagrams:

Fig 7 Wiring Gulper® IC to Whale Strainer IC

11.vii CONNECT SWITCHING CABLE

If switching cable must be fitted through bulkhead, ensure a minimum hole diameter

25mm (1") is drilled. 

Fig 8 - Connecting switching cable

through bulkhead

11.vii CONNECTING GULPER IC TO STRAINER IC (SEE FIG 1)

Connect the pre-wired Deutsch connectors on Gulper® IC and Whale Strainer IC. 

Fig 9. Connect Deutsch Connectors

Use 19mm (3/4") or 25mm (1") smooth bore reinforced pipework to connect to the

pump.

Secure the pipework on inlet and outlet with worm drive hose clip (Fig 10)

Gulper IC

Strainer IC

Deutsch

Connectors

Black

Red

Override

Switch

Battery

Isolator

Switch

On

Off

White

Off

Fuse

On

Hole diameter 25mm (1”) minimum

12. PLUMBING

Running

Light

Содержание Bilge IC Series

Страница 1: ...V d c BP2085B Gulper IC 24 V d c SI8284 Retail Bilge IC Remote Mounted Bilge Kit 12 V d c SI8484 Retail Bilge IC Remote Mounted Bilge Kit 24 V d c SI8222B Bulk Strainer IC and Gulper IC 12 V d c with...

Страница 2: ...ge pump Suitable as a primary bilge pump for boats up to 12 metres 39 4 ft designed to ISO15083 or as a secondary bilge pump on any vessel Fig 1 Typical Installation Gulper IC as a Remote Mounted Bilg...

Страница 3: ...Replacement Gulper Pump Head AK2086B Deutsch Connector Extension Cable 6m 18ft Hose Connections Gulper IC Barbed connections either 19mm or 25mm 1 Strainer IC 19mm 3 4 port Port Orientation for Strai...

Страница 4: ...FIG 9 CONNECT DEUTSCH CONNECTORS FIG 10 SECURING PIPEWORK FIG 11 STRAINER IC OPERATION TEST FIG 12 FOR CLEANING DETACH TOP COVER OF STRAINER IC FIG 13 FOR CLEANING UNSCREW VALVE HOUSING IC Intelligent...

Страница 5: ...vented loop see Fig 1 Not suitable for pumping flammable liquids diesel chemicals etc Suitable for bilge water only NOTE Bilge pump capacities may not be sufficient to prevent flooding from rapid acc...

Страница 6: ...re installing 11 i Location Choose a position to mount the pump that is dry and away from standing water and is free from obstacles Mount in a position with the shortest possible pipe run lengths 11 i...

Страница 7: ...ht connections but do not over tighten clamp rings screws hose clips Fig 3 Gulper Installation Fig 4 Fit P clamp Screw p clamp to bulkhead ensuring it is located Approx 100 mm 4 from rear housing Fig...

Страница 8: ...ump is protected against reverse polarity connection the inline fuse will blow NOTE Undersized wire in the circuit before the pump will reduce voltage when the pump is under load thus giving poor perf...

Страница 9: ...GULPER IC TO STRAINER IC SEE FIG 1 Connect the pre wired Deutsch connectors on Gulper IC and Whale Strainer IC Fig 9 Connect Deutsch Connectors Use 19mm 3 4 or 25mm 1 smooth bore reinforced pipework t...

Страница 10: ...Checks Whale advise that the boat s plumbing system is checked annually for leaks and obstructions Also a pump electrics check is advisable Before inspecting or replacing the diaphragm disconnect the...

Страница 11: ...arefully remove the lid and clean the inside walls if necessary unscrew the valve housing assembly for further cleaning Isolator switch not working not switched on Pump circuit has no power Check the...

Страница 12: ...section 14 Air leak in intake line Check hose connections are airtight Open pump head and check valves and diaphragm see section 14 Punctured pump diaphragm Replace the damaged part using service kit...

Страница 13: ...r States relating to electromagnetic compatibility Low Voltage Directive 73 23 EEC amended by 93 68 EEC on the harmonization of the laws of the Member States relating to electrical equipment designed...

Отзывы: