WD-215T
Rev. 6.0 (201812)
Instructions for use
43
(100)
NOMINAL VALUES
RESTORED FROM UI
Reset the alarm by pressing button (9). If the error recurs, contact an authorised
service company.
(4)
COMMUNICATION
ERROR BETWEEN
CPU AND I/O 1
CALL SERVICE
Restart the machine.
(5)
COMMUNICATION
ERROR BETWEEN
CPU AND I/O 2
CALL SERVICE
Restart the machine.
(6) COMMUNICATION
ERROR BETWEEN
CPU AND EXTRA CARD
CALL SERVICE
Restart the machine.
(7) COMMUNICATION
ERROR BETWEEN
CPU AND DISPLAY CARD
CALL SERVICE
Restart the machine.
(14) WEAK SIGNAL
FROM PHOTOCELL
START WASH
CLEAN PHOTOCELL
Clean the photocell. The alarm in the display will disappear after cleaning.
(47) HACCP ALARM
PUMP FUNCTIONALITY
DEFECT
PRESS RESET
Reset the alarm by pressing button (9). If the error recurs, contact an authorised
service company.
(64) HACCP ALARM
WRONG TEMPERATURE
IN TANK
PRESS RESET
Reset the alarm by pressing button (9). If the error recurs, contact an authorised
service company.
(67) HACCP ALARM
WRONG TEMPERATURE
IN BOILER
PRESS RESET
Reset the alarm by pressing button (9). If the error recurs, contact an authorised
service company.
(72) HACCP ALARM
WASHING DETERGENT
FUNCTIONALITY DEFECT
PRESS RESET
Check and fill with new detergent. Reset the alarm by pressing button (9).
(78) HACCP ALARM
FINAL RINSE
DEFECT
PRESS RESET
Open the tap. Clean the nozzles. Reset the alarm by pressing button (9).
(29)
EXTERNAL ALARM
INPUT ACTIVATED
Reset the alarm by pressing button (9). If the error recurs, contact an authorised
service company.
(30)
TIMEOUT FILLING
OF TANKS
PRESS RESET
Open the stopcocks. Close the level pipe and the outlet seals. Check the rubber
sleeves. Reset the alarm by pressing button (9).
ALARM MESSAGE
ACTION
Содержание WD-215T
Страница 51: ......