background image

Westinghouse Portable Power | 33

No.

Part.

DESCRIPTION

34

150502

FUEL COCK

35

100547

WASHER

36

120508

TOOTH TYPE GASKET Φ5

37

100548

NUT  M6

38

150512

CARBON TANK COMP

39

100512

SUPPORT,FRAME

40

100515

VIBRATION ISOLATION PAD, SQUARE

41

100518

BOLT M6X25

42

100510

FLAT WASHER Φ13XΦ37X4 

43

100506

WHEEL

44

100504

AXLE

45

100508

COTTER PIN

46

100527

PLUG, HANDLE

47

100525

BOLT, HANDLE M10XΦ12.5X53.5

48

1005221

HANDLE ASSEMBLY

49

100523

RUBBER, HANDLE

50

120509

BOLT M5X204

51

120510

NUT M5

52

120511

FLAT WASHER Ф5

53

120512

SPRING WASHER  Ф5

54

180561

GUARD COVER, CRANKCASE

55

110503

BOLT  M8X30

56

120518

BOLT  M5X16

57

100555

NEGATIVE LEAD

58

100520

NUT  M8

59

150510

CONNECTING PIPE

60

120516

GROUNDING WIRE

61

100557

BATTERY

62

100558

SHROUD, BATTERY

63

100556

POSITIVE LEAD

64

100530

SHROUD, BATTERY

-

230523

1.1L OIL BOTTLE

-

100714

REMOTE KEY FOB

WGen7500 EXPLODED VIEW PART NO. 

No.

Part.

Description

1

100500

FRAME 

2

100552

ISOLATOR B

3

100553

ISOLATOR A

4

100551

NUT M10

5

180524

NUT M8

6

150507

CONNECTING PIPE

7

180563

BRACKET, AIR CLEANER

8

120539

BOLT  M6X12

9

110504

MUFFLER BRACKET

10

180572

ENGINE ASSY

11

130508

PANEL COMP

11.1

130513

A KEY START SWITCH.

11.2

130516

SHIP TYPE SWITCH

11.3

130566

2.5MM CHARGING SOCKET

11.4

130503

THREE IN ONE DIGITAL DISPLAY.

11.5

190209

AIR SOCKET 2P/30 /31A.

11.6

130514

CIRCUIT BREAKER 20A METAL HEAD.

11.7

130505

SOCKET L14-30 R

11.8

130506

THE SOCKET

11.9

130507

THERMAL PROTECTOR

12

180562

DUSTPROOF SHEET

13

100516

BOLT  M8X16

14

120501

MOTOR ASSEMBLY

14.1

120503

GROUNDING POST COMP

14.2

120502

CARBON BRUSH COMP

15

120504

MOTOR STAND

16

100540

GASKET, ROTOR BOLT Φ10.5×Φ30×4

17

120514

BOLT M10X1.25X255

18

120513

BOLT M6X165

19

150545

CLIP, FUEL LINE Φ9X0.8

20

140508

CLIP, FUEL LINE Φ8.5

21

120537

BOLT M5X12

22

120517

AUTOMATIC VOLTAGE REGULATOR

23

120519

END COVER,GENERATOR

24

110501

GASKET, EXHAUST PIPE

25

110502

SPRING WASHER Ф8

26

110500

MUFFLER COMP

27

150500

FUEL TANK ASSEMBLY

28

120536

BOLT  M6X25

29

150547

WASHER FUEL TANK

30

100548

NUT M6

31

120528

FRAME WIRE

32

100582

BOLT M6X28

33

150505

FUEL TANK CAP COMP

Westinghouse Generator Accessories (call to order)

210004

GENERATOR COVER

210003

WGC25 25’ POWER CORD

210052

30A 6 BREAKER TRANSFER SWITCH KIT - MODEL 
WHMTS30

210075

25’ Cord 30AMP Transfer Switch

210076

50A 6 BREAKER TRANSFER SWITCH KIT - MODEL 
WHMTS50

210051

25’ Cord 50AMP Transfer Switch

Содержание WGen7500

Страница 1: ...USER MANUAL WGen7500 Portable Generator 7500 Running Watts 9500 Peak Watts REMOTE START...

Страница 2: ...to be seriously hurt or killed Model Number Running Watts Peak Watts Fuel Tank Size L G Rated Speed RPM Ignition Type Spark plug Engine Disp cc Stroke X Bore Oil Capacity L Oil Type THD WGen7500 7500...

Страница 3: ...______ Model Number _____________________________________ Last Name _______________________________________ Serial Number ______________________________________ Street Address ________________________...

Страница 4: ...Fluids and Fuel 18 Adding Gasoline to the Fuel Tank 18 How to Pair Remote Key Fob 19 Power Output and Demand 19 Starting the Generator 20 Electric Start 20 Manual Start 21 Stopping the Generator 21 N...

Страница 5: ...ot avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause da...

Страница 6: ...Never remove the fuel cap with the engine running Never refuel the generator while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank wit...

Страница 7: ...Chine CSA Master Contract Number Num ro de contrat principa l de CSA MWE Investments LLC Columbus Ohio 43228 USA Con u columbus Ohio tats Unis MWE Investments LLC Columbus Ohio 43228 Etats Unis Part N...

Страница 8: ...8 Westinghouse Portable Power SAFETY SAFETY LABELS AND DECALS 8 9 7 10 8 9 6 6 7 5 10...

Страница 9: ...manual 3 Remove the Wheel Kit Accessories cardboard box 4 Carefully cut two sides of the carton to remove the generator WHAT COMES IN THE BOX Manual Quick Start Guide Maintenance Schedule Wireless Re...

Страница 10: ...wheel kit is not intended for on road use The wheel kit is designed for use on this generator only INSTALLING FEET TO FRAME 1 Place generator on a flat surface 2 Place a piece of cardboard or other s...

Страница 11: ...iver remove the screw on the red positive battery lead 2 Securely tighten the positive battery cable red boot to the positive battery post Make sure boot is over battery post ASSEMBLY 3 Locate the bla...

Страница 12: ...ts Battery Included for electric start models Oil Fill Plug Dipstick Must be removed to add and check oil Oil Drain Plug Must be removed to drain engine oil FEATURES Never Flat Wheels For easy portabi...

Страница 13: ...r models sold into and used in California Muffler and Spark Arrester Avoid contact until engine is cooled down Spark arrestor prevents sparks from exiting the muffler It must be removed for servicing...

Страница 14: ...electronics Smart Switch Outlet Connects the Westinghouse ST Switch sold separately to the control panel Ground Terminal The ground terminal is used to ground the generator Push Button Electric Start...

Страница 15: ...utput will be reduced approximately 3 5 for every 1000ft of increased altitude from sea level This is a natural occurrence and cannot be adjusted by engine Increased exhaust emissions can also result...

Страница 16: ...n the top line of the chart Then select the rated amperage of the generator on the left side of the chart Where the two meet is the size of the conductor required for the application When using the WC...

Страница 17: ...intained during the operation of the generator Failure to maintain the proper oil level can result in engine damage OPERATION CONNECTING THE GENERATOR TO A BUILDING ELECTRICAL SYSTEM It is recommended...

Страница 18: ...ne is filled with engine oil See Checking Engine Oil on page 24 The generator is situated in a proper location Location Selection on page 15 The generator is on a dry surface Weather and Dry Surface o...

Страница 19: ...his total must not be greater than the generator s specified running power output 2 Add up the running power demand again but for the largest motor driven device use the value of its starting power de...

Страница 20: ...f using remote start then hold down START on the remote key fob until the generator starts then release see Figure 11 START STOP Figure 11 Push Button Start Remote Start The engine will automatically...

Страница 21: ...12 Figure 12 Pull recoil 8 Plug in electric devices STOPPING THE GENERATOR Normal Operation During normal operation use the following steps to stop your generator 1 Remove any connected loads from the...

Страница 22: ...tor to malfunction and could result in death or serious injury NOTICE Periodic maintenance intervals vary depending on generator operating conditions Operating the generator under severe conditions su...

Страница 23: ...muffler cover 4 Once the cover is removed locate the screw on the tip of the muffler and remove Pull the spark arrestor out of the muffler see Figure 15 Figure 15 Remove spark arrestor 5 If the spark...

Страница 24: ...Figure 18 below Figure 18 Oil Fill Plug Dipstick 6 Check oil level When checking the engine oil remove the oil fill plug dipstick and wipe it clean Thread the oil fill plug dipstick all the way back i...

Страница 25: ...apply slow but firm squeezing action 6 Rinse in clean water by submerging the air filter elements in fresh water and applying a slow squeezing action CHANGING ENGINE OIL 1 Always operate or maintain t...

Страница 26: ...ug boot by firmly pulling the plastic spark plug boot handle directly away from the engine see Figure 23 NOTICE Never apply any side load or move the spark plug laterally when removing the spark plug...

Страница 27: ...nths and run for a minimum of 15 minutes or a charger should be plugged into the generator and the generator should be charged overnight Make sure the engine control switch is in the STOP position whe...

Страница 28: ...s stuck in the cooling air inlets and exhaust ports General Cleaning of the Generator Use a damp rag to clean all remaining surfaces STORING GENERATOR WARNING Never store a generator with fuel in the...

Страница 29: ...tton on the GFCI outlet 6 If trying 1 5 above does not solve the problem the cause might be the generator has a fault 6 Take the generator to your nearest authorized service dealer Engine will not sta...

Страница 30: ...load 4 If trying 1 3 above does not solve the problem the cause might be a fault in the generator 4 Take the generator to your nearest authorized service dealer Engine runs erratic does not hold a ste...

Страница 31: ...Westinghouse Portable Power 31 WGen7500 SCHEMATIC...

Страница 32: ...32 Westinghouse Portable Power WGen7500 EXPLODED VIEW...

Страница 33: ...BRACKET 10 180572 ENGINE ASSY 11 130508 PANEL COMP 11 1 130513 A KEY START SWITCH 11 2 130516 SHIP TYPE SWITCH 11 3 130566 2 5MM CHARGING SOCKET 11 4 130503 THREE IN ONE DIGITAL DISPLAY 11 5 190209 AI...

Страница 34: ...223 CRANKCASE 2 180593 BALL BEARING 3 180504 OIL SEAL 4 190411 SEAL GOVERNOR ARM SHAFT 5 190410 SHAFT GOVERNOR ARM 6 190409 WASHER GOVERNOR ARM SHAFT 7 190408 PIN LOCK 8 180507 BOLT DRAIN PLUG 9 18050...

Страница 35: ...170503 STARTING MOTOR ASSEMBLY 89 180871 ADJUSTER ROCKER ARM 90 160037 AIR FILTER ELEMENT WGen7500 ENGINE VIEW PART NO No Part DESCRIPTION 12 180604 DOWEL PIN CASE COVER 13 190407 PISTON 14 190406 SC...

Страница 36: ...Oil Shutdown Automatic Fuel Type Unleaded Gasoline 10 Ethanol or less Fuel Shut Off Manual Fuel Tank Capacity Gallons Liters 6 6 gal 25 L Gasoline Fuel Gauge Yes Choke type Automatic Choke Location Ab...

Страница 37: ...Westinghouse Portable Power 37 Version 07 31 18KD...