background image

22 | Westinghouse Portable Power

WARNING

Avoid accidentally starting the generator during maintenance by removing the spark plug boot from the spark plug. For 
electric start generators, also disconnect the battery cables from the battery (disconnect the black negative (-) cable 
first) and place the cables away from the battery posts to avoid arcing.

Allow hot components to cool to the touch prior to performing any maintenance procedure.

Internal pressure can build in the engine crankcase while the engine is running. Removing the oil fill plug/ dipstick while 
the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely burn skin. Allow engine oil 
to cool for several minutes before removing the oil fill plug/dipstick.

Always perform maintenance in a well- ventilated area. Gasoline fuel and fuel vapors are extremely flammable and can 

ignite under certain conditions.

MAINTENANCE 

BEFORE PERFORMING MAINTENANCE ON THE GENERATOR, REVIEW THE SAFETY SECTION  START

-

ING ON PAGE 5, AS WELL AS THE FOLLOWING SAFETY MESSAGES.

MAINTENANCE SCHEDULE

WARNING

Failure to perform periodic maintenance or not following maintenance procedures can cause the generator to 

malfunction and could result in death or serious injury.

NOTICE

Periodic maintenance intervals vary depending on generator operating conditions. Operating the generator under severe conditions, 
such as sustained high-load, high-temperature, or unusually wet or dusty environments, will require more frequent periodic 
maintenance. The intervals listed in the maintenance schedule should be treated only as a general guideline.

CAUTION

Avoid skin contact with engine oil or gasoline. Prolonged skin contact with engine oil or gasoline can be harmful. 
Frequent and prolonged contact with engine oil may cause skin cancer. Take protective measures and wear protective 
clothing and equipment. Wash all exposed skin with soap and water.

TABLE 1: MAINTENANCE SCHEDULE - OWNER PERFORMED

Maintenance Item

Before Every 

Use

After First 20 

Hours or First 

Month of Use

After 50 Hours 

of Use or Every 

6 Months

After 100 Hour 

of Use or Every 

6 Months

After 300 Hours of 

Use or Every Year

Engine Oil

Check Level

Change

Change

-

-

Cooling Features

Check/Clean

-

-

-

-

Air Filter

Check

-

Clean* 

-

Replace

Spark Plug

-

-

-

Check/Clean

Replace

Spark Arrestor

-

-

-

Check/Clean

-

*Service more frequently if operating in dry and dusty conditions

Following the maintenance schedule is important to keep the generator in good operating condition. The 
following is a summary of maintenance items by periodic maintenance intervals.

Содержание WGen7500

Страница 1: ...USER MANUAL WGen7500 Portable Generator 7500 Running Watts 9500 Peak Watts REMOTE START...

Страница 2: ...to be seriously hurt or killed Model Number Running Watts Peak Watts Fuel Tank Size L G Rated Speed RPM Ignition Type Spark plug Engine Disp cc Stroke X Bore Oil Capacity L Oil Type THD WGen7500 7500...

Страница 3: ...______ Model Number _____________________________________ Last Name _______________________________________ Serial Number ______________________________________ Street Address ________________________...

Страница 4: ...Fluids and Fuel 18 Adding Gasoline to the Fuel Tank 18 How to Pair Remote Key Fob 19 Power Output and Demand 19 Starting the Generator 20 Electric Start 20 Manual Start 21 Stopping the Generator 21 N...

Страница 5: ...ot avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause da...

Страница 6: ...Never remove the fuel cap with the engine running Never refuel the generator while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank wit...

Страница 7: ...Chine CSA Master Contract Number Num ro de contrat principa l de CSA MWE Investments LLC Columbus Ohio 43228 USA Con u columbus Ohio tats Unis MWE Investments LLC Columbus Ohio 43228 Etats Unis Part N...

Страница 8: ...8 Westinghouse Portable Power SAFETY SAFETY LABELS AND DECALS 8 9 7 10 8 9 6 6 7 5 10...

Страница 9: ...manual 3 Remove the Wheel Kit Accessories cardboard box 4 Carefully cut two sides of the carton to remove the generator WHAT COMES IN THE BOX Manual Quick Start Guide Maintenance Schedule Wireless Re...

Страница 10: ...wheel kit is not intended for on road use The wheel kit is designed for use on this generator only INSTALLING FEET TO FRAME 1 Place generator on a flat surface 2 Place a piece of cardboard or other s...

Страница 11: ...iver remove the screw on the red positive battery lead 2 Securely tighten the positive battery cable red boot to the positive battery post Make sure boot is over battery post ASSEMBLY 3 Locate the bla...

Страница 12: ...ts Battery Included for electric start models Oil Fill Plug Dipstick Must be removed to add and check oil Oil Drain Plug Must be removed to drain engine oil FEATURES Never Flat Wheels For easy portabi...

Страница 13: ...r models sold into and used in California Muffler and Spark Arrester Avoid contact until engine is cooled down Spark arrestor prevents sparks from exiting the muffler It must be removed for servicing...

Страница 14: ...electronics Smart Switch Outlet Connects the Westinghouse ST Switch sold separately to the control panel Ground Terminal The ground terminal is used to ground the generator Push Button Electric Start...

Страница 15: ...utput will be reduced approximately 3 5 for every 1000ft of increased altitude from sea level This is a natural occurrence and cannot be adjusted by engine Increased exhaust emissions can also result...

Страница 16: ...n the top line of the chart Then select the rated amperage of the generator on the left side of the chart Where the two meet is the size of the conductor required for the application When using the WC...

Страница 17: ...intained during the operation of the generator Failure to maintain the proper oil level can result in engine damage OPERATION CONNECTING THE GENERATOR TO A BUILDING ELECTRICAL SYSTEM It is recommended...

Страница 18: ...ne is filled with engine oil See Checking Engine Oil on page 24 The generator is situated in a proper location Location Selection on page 15 The generator is on a dry surface Weather and Dry Surface o...

Страница 19: ...his total must not be greater than the generator s specified running power output 2 Add up the running power demand again but for the largest motor driven device use the value of its starting power de...

Страница 20: ...f using remote start then hold down START on the remote key fob until the generator starts then release see Figure 11 START STOP Figure 11 Push Button Start Remote Start The engine will automatically...

Страница 21: ...12 Figure 12 Pull recoil 8 Plug in electric devices STOPPING THE GENERATOR Normal Operation During normal operation use the following steps to stop your generator 1 Remove any connected loads from the...

Страница 22: ...tor to malfunction and could result in death or serious injury NOTICE Periodic maintenance intervals vary depending on generator operating conditions Operating the generator under severe conditions su...

Страница 23: ...muffler cover 4 Once the cover is removed locate the screw on the tip of the muffler and remove Pull the spark arrestor out of the muffler see Figure 15 Figure 15 Remove spark arrestor 5 If the spark...

Страница 24: ...Figure 18 below Figure 18 Oil Fill Plug Dipstick 6 Check oil level When checking the engine oil remove the oil fill plug dipstick and wipe it clean Thread the oil fill plug dipstick all the way back i...

Страница 25: ...apply slow but firm squeezing action 6 Rinse in clean water by submerging the air filter elements in fresh water and applying a slow squeezing action CHANGING ENGINE OIL 1 Always operate or maintain t...

Страница 26: ...ug boot by firmly pulling the plastic spark plug boot handle directly away from the engine see Figure 23 NOTICE Never apply any side load or move the spark plug laterally when removing the spark plug...

Страница 27: ...nths and run for a minimum of 15 minutes or a charger should be plugged into the generator and the generator should be charged overnight Make sure the engine control switch is in the STOP position whe...

Страница 28: ...s stuck in the cooling air inlets and exhaust ports General Cleaning of the Generator Use a damp rag to clean all remaining surfaces STORING GENERATOR WARNING Never store a generator with fuel in the...

Страница 29: ...tton on the GFCI outlet 6 If trying 1 5 above does not solve the problem the cause might be the generator has a fault 6 Take the generator to your nearest authorized service dealer Engine will not sta...

Страница 30: ...load 4 If trying 1 3 above does not solve the problem the cause might be a fault in the generator 4 Take the generator to your nearest authorized service dealer Engine runs erratic does not hold a ste...

Страница 31: ...Westinghouse Portable Power 31 WGen7500 SCHEMATIC...

Страница 32: ...32 Westinghouse Portable Power WGen7500 EXPLODED VIEW...

Страница 33: ...BRACKET 10 180572 ENGINE ASSY 11 130508 PANEL COMP 11 1 130513 A KEY START SWITCH 11 2 130516 SHIP TYPE SWITCH 11 3 130566 2 5MM CHARGING SOCKET 11 4 130503 THREE IN ONE DIGITAL DISPLAY 11 5 190209 AI...

Страница 34: ...223 CRANKCASE 2 180593 BALL BEARING 3 180504 OIL SEAL 4 190411 SEAL GOVERNOR ARM SHAFT 5 190410 SHAFT GOVERNOR ARM 6 190409 WASHER GOVERNOR ARM SHAFT 7 190408 PIN LOCK 8 180507 BOLT DRAIN PLUG 9 18050...

Страница 35: ...170503 STARTING MOTOR ASSEMBLY 89 180871 ADJUSTER ROCKER ARM 90 160037 AIR FILTER ELEMENT WGen7500 ENGINE VIEW PART NO No Part DESCRIPTION 12 180604 DOWEL PIN CASE COVER 13 190407 PISTON 14 190406 SC...

Страница 36: ...Oil Shutdown Automatic Fuel Type Unleaded Gasoline 10 Ethanol or less Fuel Shut Off Manual Fuel Tank Capacity Gallons Liters 6 6 gal 25 L Gasoline Fuel Gauge Yes Choke type Automatic Choke Location Ab...

Страница 37: ...Westinghouse Portable Power 37 Version 07 31 18KD...

Отзывы: