WESTFIRE · WF
35
4
uk
Model choice
uniq 35 standard
uniq 35 PedestaL
uniq 35 inset
50mm base
400mm pedestal
3 sided frame
4 sided frame
Closed combustion
Yes
Yes
Yes
Yes
f lue gas flow rate wood /coal test flue gas temperature wood /coal @ pascals of pressure
uniq 35
4.0/ 4.7g/sec
244/240c
12
stove model
efficiency
Weight
nominal heat output
CO@ 13% 02
Wood/coal
Wood
smokeless fuels
Wood/coal
uniq 35 standard
80.3%/76%
80kg
4.3 KW
3.7KW
.12/.17
uniq 35 pedestal
80.3%/76%
110kg
4.3KW
3.7KW
.12/.17
West fire Uniq 35
Stove Performance & testing
Westfire Uniq 35 models have been approved in accordance with EN 13240.
Preparatory Work and safety Checks – important Warning
important Warning
This stove must not be installed into a chimney that serves any other heating appliance. There must not be an
extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room.
Chimney – Chimney Connection
f lue diameter 125mm
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught so
as to clear the products of combustion and prevent smoke problems into the room.
NOTE:
A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the
chimney should be satisfactory. Alternatively the calculation procedure given in BS 5854:1980 may be used as the basis
for deciding whether a particular chimney design will provide sufficient draught.
The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building
Regulations Approved Document J.
If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow
fumes into the house. Older properties, especially, may have chimney faults or the cross section may be too large i.e.
more than 160 mm x 160 mm. Remedial action should be taken, if required, seeking expert advice. If it is found necessary
to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved
Document J.
Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the
stove. If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear
any soot falls which may have occurred due to the difference in combustion between the stove and the open fire.