7.  The paint/ lacquer can wear thin in exposed places due to overheating. This, and other lacquer damage, maybe

repaired using a Westfire Senotherm paint/lacquer spray available from your Westfire dealer.

8.  If appliance is to be dormant for several months (summer) leave open all air controls to allow a flow of air and thus

reducing probably of corrosion.

Chimney cleaning

1.  The chimney should be swept at least once a year for smokeless fuels and a minimum of twice a year for wood and

other fuels. It is important that the flue connection and chimney are swept prior to lighting up after a prolonged

shutdown period.

2.  If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear

any soot falls which may have occurred due to the difference in combustion between the stove and the open fire.

3.  In situations where it is not possible to sweep through the stove the installer will have provided alternative means,

such as a soot door.  After sweeping the chimney the stove flue outlet and the flue pipe connecting the stove to the
chimney must be cleaned with a flue brush.

Aerosols

Aerosols are flammable and therefore dangerous to use around a lit stove. Do not use aerosols sprays near your lit
stove. The use of any aerosol is dangerous and care must be take in handling aerosols.

Warning note

Properly installed, operated and maintained this stove will not emit fumes into the dwelling.  Occasional fumes from

de ashing and re fuelling may occur.  However, persistent fume emission is potentially dangerous and must not be
tolerated. If fume emission does persist, then the following immediate action should be taken:
(a)  Open doors and windows to ventilate the room and then leave the premises.
(b)  Let the fire go out.
(c)  Check for flue or chimney blockage and clean if required
(d)  Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected. If

necessary seek expert advice.

The most common cause of fume emission is flue way or chimney blockage. For your own safety these must be kept
clean at all times.

CO alarm

Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm sounds unexpectedly,

follow the instructions given under “ Warning Note” above.

Use of fireguard

When using the stove in situations where children, aged and/or infirm persons are present a fireguard must be used to

prevent accidental contact with the stove.  The fireguard should be manufactured in accordance with BS8423:2002,

Chimney f ires

If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does occur

turn the air controls on your stove to minimum, and tightly close the door of the stove. Call the fire department.
Closing the air should cause the chimney fire to go out but do not open the fire door or controls until the fire
confirmed to be exhausted. The chimney and flue ways should then be inspected and cleaned by a professional

chimney engineer before and further use.

Permanent air vent

The stove requires a permanent air vent to the room or a direct connection to the closed air port at the rear of the
stove. This is to provide adequate air supply in order for the stove to operate safely and efficiently.

Содержание WF35

Страница 1: ...WF35 1 dansk ingeniør kunst WF35 uk INSTALLATION MANUAL AND OPERATING INSTRUCTIONS d INSTALLATIONS UND GEBRAUCHSANWEISUNG fr NOTICE D INSTALLATION ET D UTILISATION nL INSTALLATIEHANDLEIDING EN GEBRUIKSAANWIJZING ...

Страница 2: ...k INSTALLATION MANUAL AND OPERATING INSTRUCTIONS 3 d INSTALLATIONS UND GEBRAUCHSANWEISUNG 18 fr NOTICE D INSTALLATION ET D UTILISATION 21 nL INSTALLATIEHANDLEIDING EN GEBRUIKSAANWIJZING 24 WF35 WESTFIRE 2013 WF35 1 0 ...

Страница 3: ...n in Approved Document J Health and safety Precautions Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met Handling Adequate facilities must be available for loading unloading and site handling fire Cement Some types of fire cement are caustic and should not be allowed to come into contact with the skin In case of contact was...

Страница 4: ...ms into the room NOTE A chimney height of not less than 4 5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory Alternatively the calculation procedure given in BS 5854 1980 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught The outlet from the chimney should be above the roof of the buildin...

Страница 5: ... bend in the chimney or connecting fluepipe should not exceed 45 90 bends should not be used If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively a draught stabiliser should be fitted The adjustable flue damper should not close off the flue entirely but should in its closed position leave a minimum continuous opening free area of at l...

Страница 6: ...on the hearth and walls adjacent to thehearth should comply with the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions If the stove is to be installed on a wooden floor it must be covered with a non combustible material at least 12mm thick in accordance with Building Regulations Approved Document J to a distanc...

Страница 7: ... run at full output for at least 24 hours On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and notify them to use only the recommended fuels for the stove Advise the user what to do should smoke or fumes b...

Страница 8: ...g Your stove Westfire uniQ 35 Controls Primary air Control settings Burning wood position 1 to position 2 When burning wood use primary air control from position 1 fully pushed in to position 2 when controls stops midway Do not move beyond this position for wood burning Burning wood position 3 to position 4 When burning coal the primary air control drops to position 3 midpoint location operate and...

Страница 9: ...e the stove door on right hand side Fully open primary air control at base left of stove Pull out riddling arm fully at base right of stove if necessary The Uniq 35 stoves air controls are now fully open 3 Light the firelighters and push door to closed position and close handle to 1st position this will allow a small gap in the door for more air to be supplied to stove during ignition period 4 Whe...

Страница 10: ...e been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be found here http smokecontrol defra gov uk Your local authority is responsible for implementing ...

Страница 11: ...ality and height of your chimney the quality of your fuel and the external weather conditions can alter the stoves operational settings and performance Very damp weather can affect the draw of the stove and therefor more secondary air may be needed to adjust Very still cold clear days induce more draught and the setting for secondary air may be less than nominal settings Such accommodations will b...

Страница 12: ...cleaning out ash embers can remain hot for over 24 hours Ash must be stored in a non combustible container and must not be mixed with other combustible waste 2 To operate riddling grate push and pull riddling arm on base right of stove using tool provided with the stove 3 Check vermiculite panels these panels can crack this will not affect performance unless the crack grows and brick break down 4 ...

Страница 13: ...persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate action should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire go out c Check for flue or chimney blockage and clean if required d Do not attempt to relight the fire until the cause of the fume emission has been ide...

Страница 14: ...on the window a The firewood may be too wet b the intake of secondary air may be insufficient c fire not hot enough 4 the stove fails to heat fully a The firewood may be too wet b the intake of secondary air may be insufficient 5 smoke or odour a Weak chimney draft b check for blockages in the flue pipe chimney c check the height of the chimney in relation to the surroundings 6 soot in the chimney...

Страница 15: ... and sealing materials such as sealing rope Consumable parts will require periodic replacement 2 Senotherm painted surfaces 3 Damage resulting from installation and usage other than as described in Westfire stoves s installation and operation instructions or if the installation does not conform to local building and fire and safety regulations 4 Defects or faults caused by local conditions such as...

Страница 16: ...oves will not in any circumstances whether under the warranty or otherwise be responsible for loss or damage you suffer that is not a foreseeable result of its breach of this warranty 1 Ensure base grate is in position 2 Place rear brick to back of stove holes uppermost 3 Fit side brick close to door slide under location point at top of top 4 Fit second side brick be tween rear brick and front sid...

Страница 17: ...l uniq35 inset Description Code Comments Brick set WF35brickset Consisting of 2x side bricks 1x rear brick 1x lower baffle brick 1 x upper baffle brick Base grate WFONEBASEGRATE Inner riddling grate WFONEINGRATE Ashpan WF35ASHPAN Door Door rope seal WF35DRS Door glass WF35GLASS Tool WF ONETWO TOOL Glove WFglove ...

Страница 18: ...en brennbaren Fußböden und der Ofenunterkante muss der Abstand mindestens 450 mm betragen Der Einsatz darf nur in eine Wand aus nicht brennbaren Materialien eingebaut werden Die Ö ffnung für den Einsatz muss mindestens 60 x 40 x 36 H B T groß sein Der Fußboden muss dort wo der Kaminofen stehen soll ausreichend tragfähig sein Der Abstand zu brennbaren Materialien gem EN 13240 geht aus dem Schild au...

Страница 19: ...stange und Ö ffnen des Lufteinlasses an der linken Seite geöffnet Zum Entzünden eignen sich Kaminanzünder gut während Brennspiritus Benzin oder andere feuergefährlichen Flüssigkeiten unter keinen Umständen verwendet werden dürfen Legen Sie einige kleinere Holzstücke über Kreuz auf die Kaminanzünder Wenn alles gut brennt werden 2 weitere Holzstücke von ca 30 cm Länge Gewicht ca 1 2 kg aufgelegt Nac...

Страница 20: ...m Material bestehen und Asche darf nicht mit anderem brennbaren Abfall in Berührung kommen Der Feuerraum ist mit Platten der Fa Skamol ausgekleidet Da sich diese Platten mit der Zeit abnutzen müssen sie ausgetauscht werden was im Ü brigen auch für die Rauchumlenkplatte gilt Wenn man ein Holzstück zu heftig in den Ofen wirft kann es passieren dass eine Skamol Platte einen Riss bekommt Das wirkt sic...

Страница 21: ...tance autorisée mais nous recommandons un espace de 10 cm derrière le poêle pour pouvoir le nettoyer La combustion demande de l air et il est donc nécessaire d avoir un apport d air frais suffisant dans la pièce où le poêle est installé Les arrivées d air doivent être placées de manière à ne pas être bloquées Il peut s agir d un clapet celui ci doit rester ouvert et avoir une capacité suffisante l...

Страница 22: ...riquettes d allumage Une fois que le feu a bien pris placez deux morceaux de bois de 30cm environ pesant en tout environ 1 2 kg Après environ 5 minutes fermez la tirette de régulation d air sur le côté gauche et fermez la tirette de régulation d air au centre environ 50 Le rechargement de bûche se fait une fois par heure à puissance nominale Pour combustion réduit lente il faut simplement ajouter ...

Страница 23: ... Il peut arriver que l une des plaques Skamol se fende après avoir été heurtée trop violemment par un morceau de bois Cela n a pas d incidence sur la combustion ce qui n est pas le cas de l inverseur de fumées Lorsque les plaques Skamol sont si usées qu elles ne sont plus entières il est temps de les remplacer C est également le cas lorsque les plaques sont fendues à plusieurs endroits En cas de s...

Страница 24: ...de afstand tot onbrandbare wanden maar in verband met het reinigen adviseren we 10 cm achter de haard De verbranding vraagt om lucht en Achterkant cm en moet Zijkant cm an verse lucht zijn naar de kamer waar de kachel staat Het toevoerkanaal voor verse lucht moet op een plaats zitten waar het niet geblokkeerd kan worden Dat kan zijn in de vorm van een ventiel het ventiel moet open staan en over vo...

Страница 25: ... met een totaalgewicht van cirra 1 2kg op Na zo n vijf minuten sluit u de primaire luchttoevoer en de secundaire tot 50 Voor afgifte van de nominale warmte zult u de kachel eens per uur moeten vullen Als u minder warmte en of langzamere verbranding wenst vult u de kachel minder vaak of met kleinere hoeveelheden U kunt dit ook regelen door de luchttoevoer tot een minimum meer dan 50 te sluiten De W...

Страница 26: ...elfde geldt voor de rookkeerplaat Als u een stuk hout te hard in de kachel gooit kan dit tot gevolg hebben dat een skamolplaat scheurt Voor de verbranding maakt dit niets uit geldt niet voor de rookkeerplaat Pas wanneer de skamolplaten zo versleten zijn dat ze niet meer heel zijn moet u deze vervangen Dit moet ook als er meerdere scheuren in de skamolplaten zitten Bij oververhitting van de houtkac...

Страница 27: ...WESTFIRE WF35 27 nL ...

Страница 28: ... FORHANDLER Der tages forbehold for trykfejl 1162 Mediegruppen Tø m r e r v e j 3 DK 6800 v a r De Te l e Fo n 45 7522 5352 Fa x 45 7522 1352 WWW We s TFir e DK e m a il in Fo We s TFir e DK WESTFIRE 2013 ...

Отзывы: