7. Power failure 

In case of power failure, the consequences are as follows: 

 

-The master clock does not distribute any impulses. The impulses are stored in the memory of 
  the master clock.  

IMPORTANT!!

  Impulses are collected for max. 10 hours.  

 
-When power returns the master clock wi11 distribute the stored impulses to the movement by  
  rapid impulses (15 imp./min.).  
 
-Then the movement begins to forward the hands to correct time. 
  
-It will take some minutes (the time depends on how long the power failure has lasted) until  
  the movement has reset the hands).  
 
-After the movement has reached correct time it returns to normal operation. 

  

 

8. Maintenance 

 
Lubrication of the movement must be done minimum once a year.All positions marked in the 
pictures on the following pages must be lubricated. 
Movement placed in aggressive environment should be lubricated at more frequent intervals, particulary the 
bearrings on the shafts and the gear mechanism. 
Use high-grade lithium-soap paste, for specification please contact Westerstrand Urfabrik AB. 
 
In case of negligence of maitenance  the movement may be damaged or the life cycle considerable reduced. 

 

 

 

 

Содержание 115000-00

Страница 1: ...synchronous motor for LMV 3 3 Check of motor before mounting of hands 4 4 Mounting of hands 4 Mounting of hands version 115014 00 LMV UV 5 5 Installation and test 5 6 Resetting Setting of correct tim...

Страница 2: ...llector The impulse collector includes an impulse controller which based on a cam and a micro switcher controls the current to the synchronus motor When the contact points of the switcher are closed t...

Страница 3: ...051 E mail info westerstrand se 2 Sketch of synchronous motor for LMV 1 Setting plate 8A Terminal for connection 230VAC 2 Drive of brass 8B Terminal for Ground connection 3 Pin 9 Minute drive 4 Hole f...

Страница 4: ...be positioned straight under the pin 3 when the P arm 5 is pressed down In this position the red arrow 6 should point straight to the 0 mark on the graded disc 1 If so continue mounting the hands see...

Страница 5: ...Connect to 230 VAC via the terminal 8A and protective earth to terminal 8B When installed a readily accessible disconnect device shall be incorporated in the fixed wiring 2 Connect the impulse wire f...

Страница 6: ...w 6 points straight to 0 mark on the setting plate 1 If not turn theminute wheel 9 anti clockwise until that position When the red arrow 6 points at 0 on the setting plate 1 this means that the moveme...

Страница 7: ...he movement begins to forward the hands to correct time It will take some minutes the time depends on how long the power failure has lasted until the movement has reset the hands After the movement ha...

Страница 8: ...RIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of driving mechanism 1 Angle gear bearing 2 Centre shaft 3 Impuls co...

Страница 9: ...B Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of gear mechanism 1 Motor shaft 2 Bearing Minute shaft 3 Bearing Minute s...

Страница 10: ...RAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Internal connection diagram 078906 00 230 VAC 50 60 Hz 24V DC reversin...

Отзывы: