background image

 

 

Dokument:  1597en06.doc 

 

Förf.:  LT/JJo 

 

 

Datum:  2017-11-30 

 

Sida:  2 av 9 

 
 
 

WESTERSTRAND URFABRIK AB 

 

 

 

Box 133 

Tel.  0506 48 000 

 

Internet:  

www.westerstrand.se 

545 23  TÖREBODA 

Fax. 0506 48 051 

 

E-mail: 

 [email protected]

 

1. General description of movement LMV 

 
The movement LMV is based on a 230V synchronous motor which moves the hands every minute via an 
echange gear mechanism. 
The movement is driven by 24V reversing impulses from a master clock, which are collected by a special  
Device, so-called impuls collector. 
The impulse collector includes an impulse controller which based on a cam and a micro switcher controls the 
current to the synchronus motor. When the contact points of the switcher are closed the motor starts. The LMV 
movement has a minute graded disc which indicates the position of the minute hand. This arrangement enable 
setting of correct time. 
The hour hand has not this feature and thus the position of the hour hand has to manually calculated and 
adjusted.  
 
The version LMV-UV complies to the feature and performance of LMV version with the exception that this 
movement only has one shaft for minute drive. This version is used for installations with separate gear for the 
hand. 
 
 
 
 
 
 
 

 

Содержание 115000-00

Страница 1: ...synchronous motor for LMV 3 3 Check of motor before mounting of hands 4 4 Mounting of hands 4 Mounting of hands version 115014 00 LMV UV 5 5 Installation and test 5 6 Resetting Setting of correct tim...

Страница 2: ...llector The impulse collector includes an impulse controller which based on a cam and a micro switcher controls the current to the synchronus motor When the contact points of the switcher are closed t...

Страница 3: ...051 E mail info westerstrand se 2 Sketch of synchronous motor for LMV 1 Setting plate 8A Terminal for connection 230VAC 2 Drive of brass 8B Terminal for Ground connection 3 Pin 9 Minute drive 4 Hole f...

Страница 4: ...be positioned straight under the pin 3 when the P arm 5 is pressed down In this position the red arrow 6 should point straight to the 0 mark on the graded disc 1 If so continue mounting the hands see...

Страница 5: ...Connect to 230 VAC via the terminal 8A and protective earth to terminal 8B When installed a readily accessible disconnect device shall be incorporated in the fixed wiring 2 Connect the impulse wire f...

Страница 6: ...w 6 points straight to 0 mark on the setting plate 1 If not turn theminute wheel 9 anti clockwise until that position When the red arrow 6 points at 0 on the setting plate 1 this means that the moveme...

Страница 7: ...he movement begins to forward the hands to correct time It will take some minutes the time depends on how long the power failure has lasted until the movement has reset the hands After the movement ha...

Страница 8: ...RIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of driving mechanism 1 Angle gear bearing 2 Centre shaft 3 Impuls co...

Страница 9: ...B Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of gear mechanism 1 Motor shaft 2 Bearing Minute shaft 3 Bearing Minute s...

Страница 10: ...RAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Internal connection diagram 078906 00 230 VAC 50 60 Hz 24V DC reversin...

Отзывы: