WRM60 X
User manual
EN
10
2.2.1.1 LG Chem batteries
Connect the battery cable eyelets: positive (+, red), negative (-, black) of the battery and the CAN communication
cable (included), as in
Pic.6
. It is also necessary to set the switches on the panel shown in
Pic.7
:
SW Select (1): Value: 0 0 1 1 (OFF OFF ON ON) (
LGC Smart - Smart communication protocol
).
Pic.6 - Power cable
Pic.7 - SWITCH settings Pic.8 - CAN LG Chem communication cable
2.2.1.2 Pylontech Batteries
Connect the quick clamps of the power cables supplied: positive (+, orange), negative (-, black) to the battery and
the CAN communication cable (included), as in
Pic.9
. Make sure that the quick clamps are correctly inserted into
the battery (you should hear a "click" once they are in the correct position).
Pic.9 - Cable installation on Pylontech battery
Internal connection to the Pylontech accumulator bank:
1.
Connect the parallel cables (ORANGE and BLACK) between the MASTER battery and SLAVE battery;
2.
connect the battery communication
LINK cable
: MASTER battery on Port 1, SLAVE battery on Port 0;
3.
set all
ADDRESS configuration switches to the OFF position
, as they are not used.
4.
Connect the CAN-BUS cable for communication with WRM60 X.
4 - INVERTER CAN
CABLE
2 - LINK SLAVE
CABLE on Port 1
6 - BUTTON
BATTERY START
2 - LINK SLAVE
CABLE on Port 0
5 - POWER
SWITCH 1
5 - POWER
SWITCH 2
1 - POSITIVE
1 - NEGATIVE
3 - SW ADDRESS
ALL OFF
Содержание WRM60 X
Страница 1: ...WRM60 X SOLAR MPPT CHARGE CONTROLLER Manuale utente User manual IT EN ...
Страница 2: ......
Страница 18: ...WRM60 X Manuale utente IT 16 Tab 3 Indicazione dei led PVA e PVB Tab 4 Funzioni dello switch a 2 posizioni ...
Страница 52: ...WRM60 X User manual EN 16 Tab 3 PVA and PVB LED indication Tab 4 Functions of the 2 position switch ...
Страница 72: ......
Страница 73: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......
Страница 78: ......