Leonardo Off-Grid 4kW/5000/48 MG
User manual
EN
9
CONTROL LOGIC
Pic.10 Control Logic
Charge and output power Table
Charge
SOC level 4
, battery energy stored
is in a range between
85% - 100%
of its
nominal capacity (Voltage > 54,4 V).
Output power
LOAD level 4
, load power
absorption is greater than
4000W.
Charge
SOC level 3
, battery energy stored
is in a range between
60% - 85%
of its
nominal capacity (Voltage > 48 V).
Output power
LOAD level 3
, load power
absorption is is in a range between
2200W - 4000W
.
Charge
SOC level 2
, battery energy stored
is in a range between
40% - 60%
of its
nominal capacity (Voltage > 46 V).
Output power
LOAD level 2
, load power
absorption is is in a range between
1000W - 2200W
.
Charge
SOC level 1
, battery energy stored
is in a range between
30% - 40%
of its
nominal capacity (Voltage > 42 V).
Output power
LOAD level 1
, load power
absorption is is in a range between
200W - 1000W
.
Tab.3 State of Charge and Output Power
Home Consumption
Inverter Limitation
PV Production
Grid Power
Battery Power