Leonardo Off-Grid 4kW/5000/48 MG
User manual
EN
4
INTERNAL OVERVIEW
Pic.3 Internal Overview
The
Leonardo Off-Grid
has an internal scheme like the one shown in the upper figure; this configuration requires the
appliance to have an AC-IN input connection from the mains, if available for the home, with a maximum alternating
input power of 5000VA.
The
Leonardo Off-Grid
has a dedicated
AC-OUT output
for the connection of domestic loads, which is also supplied in
case of BLACK-OUT.
The Energy Manager inside
Leonardo Off-Grid
takes care of the control and management of the system, ensuring a
quick display of the functioning status of the system.
The
Leonardo Datalogger
, which is external to the device and can be purchased separately, provides information on the
instantaneous power flows of the device as well as the storage of historical data of the energy produced, stored, taken
and consumed overall.
230Vac
ELECTRIC
GRID
BATTERY
I
BATT
AC
OUT1
4
LEONARDO
DATA-LOGGER
5
LEONARDO OFF-GRID
INPUT
RELAY
ISOLATED
OFF-GRID
INVERTER
AC
3
UPS
DOMESTIC
PLANT
1
230Vac
DC
CONSUMPTION
METER
AC
in
AC
out
ENERGY
MANAGER
2
AC
IN
6
DC
DC
4-INPUT MPPT
CHARGE
CONTROLLER
PV PLANT
7
KWh
Содержание Leonardo Off-Grid 4kW-5000-48 MG