9
Packaged Shock and Vibration
The shipping packaging is designed to meet the National/International Safe Transit Association (N/
ISTA) standards for packaged products. The drive incurs no physical damage when subjected to the N/
ISTA standards.
2.5.2
Temperature and Humidity
2.5.3
Thermocouple Location
Figure 2-3. Drive Base Casting Thermocouple Location
Temperature & Humidity
Operating ambient temperature
1
0
°
C to 60
°
C (32
°
F to 140
°
F)
Max base casting temperature
2
60
°
C (140
°
F)
Humidity
8-90% RH non-condensing
29.4
°
C (maximum wet bulb)
Thermal Gradient
20
°
C/hour (maximum)
Humidity Gradient
20%/hour (maximum)
Non-operating Temperature
-40
°
C to 65
°
C (-40
°
F to 149
°
F)
Humidity
5-95% RH non-condensing
40
°
C (maximum wet bulb)
Thermal Gradient
30
°
C/hour (maximum)
Humidity Gradient
20%/hour (maximum)
1
The system environment must allow sufficient air flow to limit maximum surface temperatures as defined.
2
See Figure 2-3.
Component
Location
Drive base casting