RT-220-HV / RT-220-LV User Guide
Page 18 (31)
3.2.2 Mechanical Integration, Fixing Points and Connector Positions
The product must be fixed with the four fixing points located at the corners of the product. M6 screws shall be
used for the fixation of the product. The screws shall be tightened with min. 3.0 Nm (fixing screw ISO 898/1,
quality class 8.8).
NOTICE
: All four specified fixing points must be used for fixing. The fixing surface should be flat to have all fixing
points connected to the surface.
The product has a membrane vent at the connector side of the product for equalizing pressure changes.
NOTICE
: The vent does not require any maintenance. Any manipulations at the vent are not allowed.
Specification Value
Fixing holes
positions
Fixing holes without threads, for 6mm screws: four pieces of slot holes, see: Figure 6
0 mm, 0 mm
164 mm, 0 mm
0 mm, 86 mm
164 mm, 86 mm
Connector
positions
DC POWER
Antenna 1
Antenna 2
100Base-T X1
1
100Base-T X2
See
See
See
See
See
Grounding
Table 11 Fixing points and connector positions
Figure 7 Connectors
1
PoE for RT-220-LV only