background image

RT-220-HV / RT-220-LV User Guide 

Page 11 (31) 

 

2.5 Regulatory Notices 

Caution! 

Any changes or modifications shall be approved by the party responsible for compliance. If not, users could void 

the user's authority to operate the equipment. 

Country code and antenna gain needs to be set properly for correct functionality in the installed country. 

2.5.1 United States (FCC) 

The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, 

including interference that may cause undesired operation. 

Contains FCC ID: 

2AEJD-103902-DT50RF 

RF Exposure requirements: 

To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more 

should be maintained between the antenna of this device and persons during operation. To ensure compliance, 

operations at closer distances than this are not recommended. 

Antennas: 

The device can operate with the antennas listed in 2.5.3. 

Part 15B statement: 

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 

part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 

in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does 

cause harmful interference to radio or television reception, which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

2.5.2 Canada (IC) 

This device com

plies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two 

conditions: 

1.  This device may not cause interference. 

2.  This device must accept any interference, including interference that may cause undesired operation of 

the device. 

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de 

licence. 

L’exploitation est autorisée aux deux conditions suivantes: 

Содержание RT-220-HV

Страница 1: ...REV A 6623 2240 2019 11 Westermo Network Technologies AB Sweden RT 220 HV RT 220 LV User Guide...

Страница 2: ...RT 220 HV RT 220 LV User Guide Page 2 31...

Страница 3: ...rties including Free Libre Open Source Software FLOSS The specific license terms and copyright associated with the software are included in each software package respectively Please visit the product...

Страница 4: ...llation Considerations 19 3 3 2 Temperature Alarms 19 3 3 3 Ambient Operating Temperature Range 19 3 3 4 Installations at Very High Temperatures 20 3 4 Connecting the Protective Earth 22 3 5 Connectin...

Страница 5: ...s and Ethernet LEDs 28 Figure 16 Ethernet Port for Factory Reset 28 Figure 17 Factory reset plug D coded 29 Table 1 Supported product versions variants and SW 9 Table 2 Important safety notes 9 Table...

Страница 6: ...loss of data or income or any special incidental and consequential or indirect damages howsoever caused More information about Westermo can be found at www westermo com 1 2 References and related doc...

Страница 7: ...RT 220 HV RT 220 LV User Guide Page 7 31 SNMP Simple Network Management Protocol WebGUI Web Graphical User Interface WLAN Wireless Local Area Network...

Страница 8: ...onfigured either as Access Point or Station The Westermo configuration management tool WeConfig can be used for discovery and basic configuration and maintenance The configuration can be done via SNMP...

Страница 9: ...r accessories such as damaged power cord Danger Never try to open the device There are no serviceable parts inside By trying to open the device you will be exposed to a risk of death or injury Warning...

Страница 10: ...y Code Operating Frequency Ranges Notes Europe EU 2412 2472 MHz and 5180 5320 MHz 5500 5700 MHz Operation according to ETSI limitations For detailed specification refer to document Software 6 Manageme...

Страница 11: ...e FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy a...

Страница 12: ...rt number Manufacturer Gain Chains Antenna Type ID Dipole F51 N Tekfun 2 GHz 4 5 dBi max 5 GHz 7 dBi max 1 2 1001 Patch SPA 2400 75 8 0 V Huber Suhner 2 GHz 7 5 dBi max 1 2 1000 Patch SPA 5600 40 14 0...

Страница 13: ...fication label example Specification Value Notes Product Name RT 220 HV RT 220 LV Depending on voltage variant Part Number 3623 072301 RT 220 HV EU 3623 072201 RT 220 LV EU 3623 072302 RT 220 HV NA 36...

Страница 14: ...unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring this product is disposed of co...

Страница 15: ...r installation See chapter 3 4 3 Antennas The antenna interfaces are installed based on customer requirements See chapter 3 5 4 Ethernet The Ethernet data interfaces are installed See chapter 3 6 5 Po...

Страница 16: ...RT 220 HV RT 220 LV User Guide Page 16 31 3 2 Dimensions for Fixing Points 3 2 1 Mechanical Overview Figure 6 Mechanical overview...

Страница 17: ...ith antenna connectors 180mm Maximum dimensions with cables but not including antennas Approx 300 x 110 x 52 mm Space needed for installation Location of the fixing points In each corner With four M6...

Страница 18: ...face The product has a membrane vent at the connector side of the product for equalizing pressure changes NOTICE The vent does not require any maintenance Any manipulations at the vent are not allowed...

Страница 19: ...erature Range This product includes a vent allowing controlled air exchange due to temperature changes Humidity is blocked by the vent To ensure correct operation over the whole specified temperature...

Страница 20: ...re the product is operated close to its maximum specified ambient temperature 55 C TAmbient 70 C it must be ensured that the natural convection is not blocked by objects close to the product Figure 8...

Страница 21: ...the device at ambient temperatures above app 60C it is recommended to mount the device to a metallic base plate to improve the heat dissipation The base plate increases the surface to spread the heat...

Страница 22: ...11 Grounding contact 3 5 Connecting the RF Antenna Interfaces 3 5 1 RF Antenna Interface Operation Modes RT 220 has two antenna interfaces The antenna interfaces are operating independently of each o...

Страница 23: ...might be fixed in antenna connectors directly or using antenna cables fixed to the antenna connectors Figure 12 Antenna interfaces NOTICE If one of the antennas is NOT used the unused antenna connecto...

Страница 24: ...a transformer in the signal lines There is no additional line protection for Lightning etc included at product hardware module 3 6 1 Ethernet Port Features The Ethernet port supports the following net...

Страница 25: ...compliant to IONA Industrial Ethernet Planning and Installation Guide Release 4 0 3 6 3 PoE Connection X1 and RT 220 LV only Connector Pin 1000 mode A Notes 1 2 DC Connector Type Industrial ETHERNET...

Страница 26: ...rect connector position NOTICE The Power Feed Cable is not part of delivery 3 7 1 Power Feed Connector Connector type M12 A coded 4 pin male connector according to IEC 61076 2 101 Figure 14 RT 220 pow...

Страница 27: ...App 8W App 4W App 8W with no user data with full user data load Selecting external power connector and power cable diameter Allowed wire cross section Min 0 5mm2 Min 0 5mm2 Cable Plug e g Phoenix Con...

Страница 28: ...Figure 15 Power operation status and Ethernet LEDs 4 2 Factory Reset Interface Process for Factory Reset A factory reset is not typically needed for installation It is required if the device configur...

Страница 29: ...ter that is connected to one of the Ethernet ports during the start up Step Description 1 Plug the factory reset adapter to one of the Ethernet interfaces 2 Power the device 3 Wait until factory reset...

Страница 30: ...only 5 1 Cleaning Resistance to Chemicals In case the product is cleaned with cleaning chemicals the resistance to chemicals of the plastic parts needs to be respected The following plastic materials...

Страница 31: ...tep Description 1 Remove Cables Remove cables in the following order 1 Power cable or PoE cable 2 Antenna cables 3 Ethernet cables 4 Protective earth cable 2 Open Screw The four M6 screws in each corn...

Отзывы: