38
6193-3201
3.16 Configuration Examples
Setting a RM-90 to Factory Default Settings
Access configuration webpages of RM-90. Refer section
Accessing Configuration inside a
module for the first time
, or
Modifying an existing configuration
.
1. Click on System Tools Menu Item
2. Enter username “user” and password “user”, when prompted for password.
Click on Factory Default Configuration Reset, and wait for unit to reset. When reset, the
LINK LED will flash.
Extending a wired network
Access Point Configuration
Connect straight through Ethernet cable between PC and RM-90.
… Ensure configuration PC and RM-90 are setup to communicate on the same network
… Set dipswitch to SETUP mode.
… Power up unit, and wait for LINK led to cease flashing.
… Adjust PC network settings
Set Configuration PC network card with network setting of IP address 192.168.0.1,
netmask 255.255.255.0
… Open configuration webpage with Internet Explorer at address http://
192.168.0.1XX/ where XX is the last two digits of the serial number
When prompted for password, enter default username “user” and password “user”
Enter “Quick Start”, and select Access Point.
Change the IP address to 192.168.0.200
Enter a System Generator String
Select the Radio Encryption required.
Set dipswitch to RUN
Save the changes and unit will restart with new settings.