39
6193-3201
Alternate procedure
– Adjust RM-90 network settings using serial
port(assuming configuration PC is on existing network)
a) Open terminal program with settings with data rate 19200bps, 8 data bits, 1
stop bit and no parity.
b) Set dipswitch to SETUP
c) Connect straight through serial cable to RM-90 and power up unit.
d) When prompted, strike the Enter key to abort automatic boot
e) Set IP address of RM-90 to 192.168.0.200 with command bip 192.168.0.200
f) Set netmask of RM-90 to 192.168.0.200 with command bnm 255.255.255.0
g) Set gateway address of RM-90 to 192.168.0.1 with command bgw 192.168.0.1
h) Set dipswitch to RUN
i) Reset RM-90 with reset command.
j) Open configuration webpage with Internet Explorer at address
http://192.168.0.200/
When prompted for password, enter default username “user” and password
“user”
Enter “Quick Start”, and select Access Point.
IP address should be 192.168.0.200
Enter a System Generator String
Select the Radio Encryption required.
Save the changes.
Client 1 Configuration
Perform the same configuration steps as the Access Point configuration with the follow-
ing differences:
… set IP address of RM-90 to 192.168.0.201
… set the Operating Mode to Client.
Ensure the same System Generator String is used and the same Radio Encryption meth-
od is selected.
Client 2 Configuration
… As above, but use IP address 192.168.0.202
Connecting two separate networks together
6XXZhhEd^ci
GdjiZg
A6C6
A6C7
8a^Zci
7g^Y\Z
&.'#&+-#%#%
'**#'**#'**#%
>ciZgcZi
&+.#'*)#&%'#*%
'**#'**#'**#%
&+.#'*)#&%'#*)
&+.#'*)#&%'#*(