Class C
Class D
Class E
Remarks
Temperature
X
X
X
Relative humidity
X
X
X
Vibration
X
X
X
Mechanical shock
X
X
X
Dielectric strength
X
Tested with 1.5 kVAC rms
Table 4. AREMA Part 11.5.1. - Environmental Class
External
Internal
Enclosure port
Radiated RF immunity
Power Frequency Magnetic Field
Pulse Magnetic Field
X
X
X
X
X
X
DC power port
EFT/Burst
Surge (1.2/50
μ
s)
Conducted RF
X
-
X
X
X
X
DI-, DO-port
EFT/Burst
Surge (1.2/50
μ
s)
Conducted RF
X
-
X
X
X
X
Ethernet ports
EFT/Burst
Surge (1.2/50
μ
s)
Conducted RF
X
X
X
X
X
X
Serial ports
EFT/Burst
Surge (1.2/50
μ
s)
Conducted RF
X
X
X
X
X
X
Table 5. AREMA Part 11.5.2. - Exposure Class
AREMA Part 11.3.3.E. - Equipment surge withstand documentation DC power port
1. Maximum normal circuit voltage when powered from a vital signal battery is 24 VDC
otherwise 48 VDC
2. Surge protection clamping voltage is 87.1 VDC
3. Maximum energy handling capability is 5 J, 1 ms
2.5.4. Corrosive Environment
This product has been successfully tested in a corrosion test according to IEC 60068- 2-60,
method 3. This means that the product meets the requirements to be placed in an
environment classified as ISA-S71.04 class G3.
10
Lynx L108/208-F2G-S2
Содержание Lynx DSS L108-F2G-S2 EX
Страница 1: ...www westermo com OS Lynx L108 208 F2G S2 Industrial Ethernet 8 Port Device Server Switch...
Страница 3: ...5 2 Type Tests and Environmental Conditions 29 6 Revision Notes 32 Lynx L108 208 F2G S2 3...
Страница 33: ...Lynx L108 208 F2G S2...
Страница 34: ...Lynx L108 208 F2G S2...
Страница 35: ...Lynx L108 208 F2G S2...