background image

3. Product Description

3.1. Product Description

The Lynx series consists of layer 2 or layer 3 industrial Ethernet switches, powered by
WeOS, the Westermo network operating system. The Lynx switches are the most
compact switches or device servers on the market, available with various ports depending
on model, whereof two are 100 Mbit or Gbit SFP transceivers.

The Lynx series is designed for simple use in industrial applications, from the robust DIN
rail clip solution to the configurable fault contact and the industrial level of dual power
inputs.

Only industrial grade components are used which ensures a long service life. A wide
operating temperature range of -40 to +70°C (-40 to +158°F) can be achieved with no
moving parts or cooling holes in the case.

The Lynx series has been tested both by Westermo and external test institutes to meet
many EMC, isolation, vibration and shock standards, all to the highest levels suitable for
heavy industrial environments and rail trackside applications.

WeOS has been developed by Westermo to offer cross platform and future proof
solutions. WeOS delivers unique functionality in legacy IP solutions, supporting Modbus
Gateway, virtual COM, modem replacement or several options in dual TCP applications.
For more WeOS functionality, please see the WeOS datasheet.

3.2. Available Models

Art. no.

Model

100 Mbit
TX ports

Gbit SFP
ports

Serial
ports

Software

Rated
voltage

3643-0200

L108-F2G-S2

4

2

2

L2

24-48 VDC

3643-0240

L108-F2G-
S2-12VDC

4

2

2

L2

12-24 VDC

3643-0205

L208-F2G-S2

4

2

2

L3

24-48 VDC

12

Lynx L108/208-F2G-S2

Содержание Lynx DSS L108-F2G-S2 EX

Страница 1: ...www westermo com OS Lynx L108 208 F2G S2 Industrial Ethernet 8 Port Device Server Switch...

Страница 2: ...implified Declaration of Conformity 11 3 Product Description 12 3 1 Product Description 12 3 2 Available Models 12 3 3 Hardware Overview 13 3 4 Connector Information 14 3 4 1 Ethernet Connection TX 14...

Страница 3: ...5 2 Type Tests and Environmental Conditions 29 6 Revision Notes 32 Lynx L108 208 F2G S2 3...

Страница 4: ...stermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available a...

Страница 5: ...rdous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides i...

Страница 6: ...cross sectional area of at least 4 mm2 If the product does not have a protective earthing terminal then the DIN rail must be connected to protective earth Upon removal of the product ensure that the p...

Страница 7: ...ective plugs on the transmitter receiver must be connected The protective plugs must be kept on during transportation The fibre optics cables must be handled the same way CAUTION CORROSIVE GASES If th...

Страница 8: ...tion the protection provided by the equipment may be impaired If the product is not working properly contact the place of purchase nearest Westermo distributor office or Westermo technical support 2 4...

Страница 9: ...es uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee th...

Страница 10: ...1 2 50 s Conducted RF X X X X X X Serial ports EFT Burst Surge 1 2 50 s Conducted RF X X X X X X Table 5 AREMA Part 11 5 2 Exposure Class AREMA Part 11 3 3 E Equipment surge withstand documentation DC...

Страница 11: ...d corrosion attacks on the gold plated connector pins 2 5 5 Simplified Declaration of Conformity Hereby Westermo declares that this product is in compliance with applicable EU directives The full EU d...

Страница 12: ...to 158 F can be achieved with no moving parts or cooling holes in the case The Lynx series has been tested both by Westermo and external test institutes to meet many EMC isolation vibration and shock...

Страница 13: ...ection 5 I O connection 6 Ethernet connection 7 RS 232 connection 8 RS 232 and RS 422 485 connection Figure 3 Location of interface ports and LED indicators 3 2 1 No Description No Description 1 I O c...

Страница 14: ...ription 1 2 3 4 1 DC1 Input Supply voltage 2 DC2 Input Supply voltage 3 COM Input Common 4 COM Input Common Table 7 Power input The product supports redundant power connection The positive inputs are...

Страница 15: ...n opto isolated digital input which can be used to monitor external events For voltage current see Interface Specification section External load Status V V Digital in Lynx 3 4 1 2 Figure 5 Digital in...

Страница 16: ...used 5 Not used 6 R In RS 422 Receive 7 Not used 8 Not used Table 10 RS 422 485 connection Lynx is equipped with with an internal termination that is configurable through software in RS 422 485 mode...

Страница 17: ...NOTE The port is configurable for both RS 232 and RS 422 485 hence no fail safe biasing is available for RS 422 485 signals 3 4 6 USB Connection Illustration Pin no Direction Description 1 Out VBUS 2...

Страница 18: ...configured as FRNT focal point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Product selected as RSTP STP root switch USR1 Configurable see WeOS Management Guide Rx TD TD OFF No serial data receive...

Страница 19: ...cepts Westermo branded transceivers only From 4 5 0 other transceivers are accepted with a notice and the product will no longer be UL approved Temperature specifications are also depending on the use...

Страница 20: ...3 9 Dimensions Dimensions are stated in mm and are regardless of Lynx model 92 1 Min 4mm Max 7 5mm 34 1 96 1 52 1 100 1 Figure 8 Dimensional drawing 20 Lynx L108 208 F2G S2...

Страница 21: ...mmended that the DIN rail is connected to ground Snap on the product to the DIN rail according to the figure Figure 9 Mounting of product 4 2 Removal of Product This product has an integrated DIN clip...

Страница 22: ...he unit WeConfig tool This is a custom Westermo tool used for discovery of attached Westermo product Web Configuration of the product using the web browser CLI Configuration of the product via the Com...

Страница 23: ...password character NOTE Note Version of WeConfig tool must be 10 3 0 or higher 4 6 Factory Default It is possible to set the product to factory default settings by using two straight standard Ethernet...

Страница 24: ...product will restart with factory default settings When the product has booted up the ON LED will show a green light and is now ready to use To boot as normal To skip the factory reset process just wa...

Страница 25: ...0 mA USB load Rated frequency DC Inrush current I t 102 mA2s at 12 VDC 71 2 mA2s at 24 VDC 22 7 mA2s at 48 VDC Startup currenta 2 x rated current Polarity Reverse polarity protected Redundant power in...

Страница 26: ...t s 1000 Mbit s transceivers supported Duplex Full or Auto depending on transceiver Transmission range Depending on transceiver see datasheet for SFP transceivers Connection SFP slot holding fibre tra...

Страница 27: ...as signalling and telecommunications apparatus and located close to railsa Conductive chassis Yes Number of ports 1 aTo minimise the risk of interference a shielded cable is recommended when the cable...

Страница 28: ...ge 0 3 Nm USB Electrical specification USB 2 0 host interface Data rate Up to 12 Mbit s full speed mode Circuit type SELV Maximum supply current 400 mA Connection USB receptable connector type A Conso...

Страница 29: ...22 485 L E 2 kV 42 0 5 F Power frequency magnetic field EN 61000 4 8 Enclosure 300 A m 0 16 7 60 Hz 1000 A m 50 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4...

Страница 30: ...viation 15 cm Steering standby steering emergency compass 18 H deviation 10 cm Dielectric strength EN 60950 1 Power port to all other ports 1 5 kVrms 50 Hz 1 min Ethernet ports to all other ports RS 2...

Страница 31: ...6 sine Operational 3 13 2 Hz 1 mm 13 2 100 Hz 0 7 g 5 5 30 Hz 1 5 g 30 50 Hz 0 42 mm 50 500 Hz 4 2 gb IEC 60068 2 64 random Operational 5 20 Hz 2 m2 s2 20 2000 Hz 3 dB oct Shock IEC 60068 2 27 Operat...

Страница 32: ...updated 3 7 Supported Transceivers updated 4 2 Removal of Product updated Rev M 2019 09 2 6 1 Agency Approvals and Standards Compliance updated 2 6 3 New chapter 3 1 Product Description updated 5 1 I...

Страница 33: ...Lynx L108 208 F2G S2...

Страница 34: ...Lynx L108 208 F2G S2...

Страница 35: ...Lynx L108 208 F2G S2...

Страница 36: ...Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6643 2220 REV N 2020 10 Westermo Network Technologies AB Sweden...