RS-422/485
Electrical specification
Configurable for EIA RS-232 or EIA RS-422/485
Data rate
50 bit/s - 2 Mbit/s
Data format
7 or 8 data bits, odd, even or none parity, 1 or 2 stop bits (2 stop bits only
when no parity is set)
Circuit type
TNV-1
Transmission range
Up to 1200 m/0.74 mi, depending on data rate and cable type
Isolation
To all other ports
Connection
RJ-45 according to EIA-561
Shielded cable
Shielded cable not required, except when installed in Railway application
as signalling and telecommunications apparatus and located close to rails
a
Conductive chassis
Yes
Number of ports
1
a
To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.
I/O connection, Relay output
Maximum voltage/current
60 VDC/80 mA
Connect resistance
Maximum 30
Ω
Isolation
To all other ports
Connector
Detachable screw terminal
Conductor cross section
0.14 - 1.5 mm² (AWG 28 - 16)
Stripping length cable
7 mm
Tightening torque, terminal
screw
0.22 - 0.25 Nm
Tightening torque, screw
flange
0.3 Nm