background image

Industrial Ethernet adapter

INSTALLATION MANUAL

6609-2202

www.westermo.se

ED-10

©

Westermo 

Teleindustri 

AB 

• 

2001 

• 

REV. 

A

Galvanic

Isolation

Transient

Protection

Balanced

Transmission

CE

Approved

Содержание ED-10 TCP

Страница 1: ...Industrial Ethernet adapter INSTALLATION MANUAL 6609 2202 www westermo se ED 10 Westermo Teleindustri AB 2001 REV A Galvanic Isolation Transient Protection Balanced Transmission CE Approved...

Страница 2: ......

Страница 3: ...s 8 10 4 2 DIP switch settings 11 4 3 LED indicators 12 4 4 Installation of ED Tool 13 5 Functional description 14 15 6 Configuration 16 6 1 Configuration by ED Tool 16 22 6 2 Configuration by termina...

Страница 4: ...ssible to communicate one to many e g master slaves by using a broad cast address If the customer writes it s own PC application software the network interface of ED 10 can be directly accesed A softw...

Страница 5: ...P for transmitting the serial data over network i e UDP is used in application mode UDP uses packet delivery of data meanwhile TCP uses stream transport The ED 10 can be configured both remotely over...

Страница 6: ...n female D sub Power Interface Rated voltage 12 49 V AC 10 74 V DC polarity independent Rated current 350 mA Rated frequency 50 60 Hz Mechanical Screw Terminal Isolation Functional and safety Power In...

Страница 7: ...nterface Windows based PC programme or simple terminal programme Delayed configure possible Indicators LED TD RD CTS RTS PWR TD RD CONFIG NET Environment 5 50 C 5 95 REL non condensing Dimension 55x10...

Страница 8: ...24 RS 232C Direction Description 1 DCD 109 CF Out Data Carrier Detect 2 RD 104 BB Out Received Data 3 TD 103 BA In Transmitted Data 4 DTR 108 2 CD In Data Terminal Ready 5 SG 102 AB In out Signal Grou...

Страница 9: ...le is recommended CH2 RS 232 Connections D sub connector DCE 5 4 3 2 1 9 8 7 6 Pin Signal Name Number Description V 24 RS 232C Direction Description 1 DCD 109 CF Data Carrier Detect not connected 2 RD...

Страница 10: ...Name Direction1 Description 1 TD Out Transmitted Data 2 TD Out Transmitted Data 3 RD In Received Data 4 Not connected 5 Not connected 6 RD In Received Data 7 Not connected 8 Not connected Direction re...

Страница 11: ...6 7 8 S1 2 wire Factory settings ON 1 2 3 4 5 6 7 8 S2 Channel 2 ON 1 2 3 4 5 6 7 8 S1 Channel 1 Termination and fail safe 4 wire Channel 1 ON 1 2 3 4 5 6 7 8 S1 Termination and fail safe off ON 1 2 3...

Страница 12: ...end LED off RS 232 CTS Off 3V RS 422 485 transmitting LED on RS 232 CTS On 3V RS 422 485 receiving PWR Power LED off No internal power external power not connected LED on Power OK CH2 TD Transmitted D...

Страница 13: ...24 MB of RAM for Windows NT systems 32 MB of RAM for Windows 2000 systems CD ROM drive 8 MB of space on hard drive Serial and or ethernet network connections Internet Explorer 5 0 or higher Recommend...

Страница 14: ...le parameters are listed in chapter 6 4 Application mode In application mode the ED 10 transfers data between the serial interface CH1 and the network interface 10BaseT At the network interface data a...

Страница 15: ...ate one to many e g master slave by using a broadcast IP address e g 255 255 255 255 Both directed and limited broadcast is supported Configuration mode Local or remote configuration is managed by eit...

Страница 16: ...0 or by opening a configuration file stored on the system Or the user can set all configuration parameters by hand To configure an ED 10 the user must set all parameters After the parameters are set t...

Страница 17: ...a click on a button or by a menu option The commands are described by there use 1 2 3 4 5 1 2 3 4 5 Reads configuration parameters from attached ED 10 Writes configuration parameters to ED 10 ED 10 m...

Страница 18: ...ion file File New Default parameters are set Load configuration file File Load Load a pre stored configuration file from the system Save configuration file File Save Save a configuration file or syste...

Страница 19: ...Button Exit File Exit ED Tool close and exit Read configuration file Tools Read Configuration parameters are read from an ED 10 Write configuration file Button Write Tools Write Configuration paramete...

Страница 20: ...20 6609 2202 Reboot Button Reboot Tools Reboot ED 10 reboots View configuration file Tools View File Files are viewed correctly in a View window...

Страница 21: ...21 6609 2202 Set connection Tools Serial Serial and network connection parameters are displayed and can be altered Help Help ED Tool help system not currently used...

Страница 22: ...chip set ini factory set ini delayed set ini See chapter 6 4 Values used at re boot are stored in the chip set ini files The files delayed set ini holds values used if delayed configuration is activa...

Страница 23: ...URATION MODE datarate 19200 Request a data rate of 19 200 bit s ok localip 192 168 12 12 Request local IP address to be 192 168 12 12 ok localport 9000 Request 9000 as local protocol port ok exit Esta...

Страница 24: ...ss of ED 10 working mode Parameters that can be altered their allowed values and in which file they appear can be found in chapter 6 4 config urable parameters Text in terminal window Explanation type...

Страница 25: ...stance weekends or nights Automatic re configure is easy activated using ED Tool 1 Press Read config button The active old configuration will be shown 2 Check the Delayed Config and insert the request...

Страница 26: ...Protocol port ok configuredelay 360 Request re configure after 6 hours ok exit Updates configuration files and ensures application mode after a re boot Copied app bat to autoexec bat Parameters succes...

Страница 27: ...files DATARATE DATABITS PARITY STOPBITS FLOWCONTROL Remarks 0 none 1 odd 2 even Two stop bits only when no parity is selected 0 NO 1 HW Parameter End of Frame Character ASCII value End of Frame Delay...

Страница 28: ...ini files IP ADDRESS IP GATEWAY IP NETMASK TELNET USER0 USER1 TELNET PASSWORD0 PASSWORD1 Apperance in set files LOCALPORT REMOTEIP REMOTEPORT CONFIGUREDELAY Remarks IP Addr in dotted decimal notation...

Страница 29: ...ntrol is ignored for port type RS 422 485 Default flow control is switched off none and the CTS will follow DSR Termination and Failsafe Only by switches Termination and fail safe is used for port typ...

Страница 30: ...n network MTU if fragmentation shall be avoid Local IP address Local IP address is used as the first part of local end point identity in both application and configuration mode 10 0 0 10 is used as de...

Страница 31: ...P address is used as the first part of the remote end point identity in applica tion mode 10 0 0 10 is used as default Any received data at serial interface 1 CH1 will be echoed back as long as defaul...

Страница 32: ...B A S E T CHANNEL 4 RS 232 o r R S 4 2 2 4 8 5 RS 232 or RS 422 485 RS 232 or RS 422 485 32 6609 2202 1 Application examles Example of IP address setting in an multi drop application Note IP addresses...

Страница 33: ...2 o r R S 4 2 2 4 8 5 33 6609 2202 IP addresses and ports settings example for a serial point to point connection over network If remote point is on different network gateway address have to be set ac...

Страница 34: ...essed by an PC application will work with the software example udptest exe see www westermo se download area Example of necessary network setting of PC Win 98 ED 10 default settings RS 232 or RS 422 4...

Страница 35: ......

Страница 36: ...Unit 14 Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Web www westermo co uk Westermo Data Communication...

Отзывы: