background image

3

6642-22303

Safety

Before installation:

Read this manual completely and gather all information on the unit. Make sure 
that you understand it fully. Check that your application does not exceed the safe 
operating specifications for this unit. 
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is 
restricted to service personnel only.
The power supply wiring must be sufficiently fused, and if necessary it must be 
possible to disconnect manually from the power supply. Ensure compliance to 
national installation regulations.
This unit uses convection cooling. To avoid obstructing the airflow around the unit, 
follow the spacing recommendations (see Cooling section).

Before mounting, using or removing this unit:

Prevent access to hazardous voltage by disconnecting the unit from power supply.
Warning! Do not open connected unit. Hazardous voltage may occur within this 
unit when connected to power supply.

Care recommendations

Follow the care recommendations below to maintain full operation of unit and to fulfil 
the warranty obligations.
This unit must not be operating with removed covers or lids.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit, rough handling above the specification may cause 
damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not 
waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical 
part may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Westermo 
distributor office or Westermo Tech support.
A readily accessible disconnect device shall be incorporated external to the equipment.
This unit may have hot surfaces when used in high ambient temperature.

WARNING:

When this unit is operated at an ambient temperature above +60°C, the External Surface 
of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1.

Maintenance

No maintenance is required, as long as the unit is used as intended within the specified 
conditions.

!

!

Содержание 3642-0240

Страница 1: ...www westermo com Westermo Teleindustri AB User Guide 6642 22303 Industrial Ethernet SHDSL extender DDW 225 DDW 225 W O LV E R I N E S E R I E S WeOS...

Страница 2: ...ty or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of...

Страница 3: ...o fulfil the warranty obligations This unit must not be operating with removed covers or lids Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock or sha...

Страница 4: ...nce in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference...

Страница 5: ...ity No Title Issue EN 61000 6 1 Electromagnetic compatibility Immunity for residential environments 2007 EN 61000 6 2 Electromagnetic compatibility Immunity for industrial environments 2005 EN 61000 6...

Страница 6: ...N 61000 4 29 DC power ports 10 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage Radiated emission CISPR 16 2 3 ANSI C63 4 FCC part 15 Enclosure Class A and Class B...

Страница 7: ...tatus 3 IO Digital in Uin 60 VDC max Uin 10 mA max 4 IO Digital in M5 threaded hole for PE connection Position Direction descripton Input Output values 1 In out GND U 3 3 VDC max I 24 mA max 2 Out Tx...

Страница 8: ...of advanced diagnostic functions that allow the SHDSL line to be dynamically monitored allowing alarms to be configured to pre warn of any performance issues This monitoring data can be accessed in a...

Страница 9: ...polarity protected Redundant power input Yes Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required External supply current capab...

Страница 10: ...LV Maximum supply current 500 mA Isolation to All other except Console Galvanic connection to Console Connection USB receptacle connector type A Conductive housing Yes Connection to console port The c...

Страница 11: ...ocated close to rails Conductive housing Yes Number of ports 4 To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary or the cable is longer...

Страница 12: ...2 wire Receive Transmit SHDSL 2 In Out 2 wire Receive Transmit SHDSL Position Direction Description 1 2 3 4 1 Out Status 2 Out Status 3 In Digital in 4 In Digital in Direction relative this unit Posit...

Страница 13: ...cription 1 Out VBUS 2 In Out D 3 In Out D 4 Out GND Shield In Out Connected to PE Console see more information on page 14 Position Direction Description 1 In Out TD 2 In Out TD 3 In Out RD 4 Not conne...

Страница 14: ...ED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root switch VPN OFF VPN disabled GREEN Configurable Default At least on...

Страница 15: ...N rail TH 35 15 according to EN 60715 CLICK Wall mounting This unit can also be wall mounted see figure Earth connection For correct function the ground connection on the unit needs to be properly con...

Страница 16: ...the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Con...

Страница 17: ...o ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging one of the Ethernet cables T...

Страница 18: ...18 6642 22303...

Страница 19: ......

Страница 20: ...e North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co...

Отзывы: