I/O / Relay output 

Connect resistance

30 

W

Isolation to 

All other

Connection

Detachable screw terminal

Connector size 

0.2 – 2.5 mm

2

 (AWG 24 – 12)

Maximum voltage/current

60 VDC / 80 mA

I/O / Digital input

Voltage levels

Logic one >12V, Logic zero <1V

Isolation to 

All other

Connection

Detachable screw terminal

Connector size 

0.2 – 2.5 mm

2

 (AWG 24 – 12)

USB

Electrical specification

USB 2.0 host interface

Data rate

Up to 12 Mbit/s (full-speed mode)

Circuit type

SELV

Maximum supply current

500 mA

Isolation to

All other except Console

Galvanic connection to

Console

Connection

USB receptacle connector type A

Conductive housing

Yes

Connection to console port

The console port can be used to connect to the CLI  
(Command Line Interface).

The following steps needs to be taken

1.  Connect the serial diagnostic cable to the console port  

(use only Westermo cable 1211-2027).

2.  Connect cable to your computer (USB port, if drivers are 

needed they can be downloaded from our Web page).

3.  Use a terminal emulator and connect with correct speed and 

format to the assigned port. 

For more information about the CLI, see the WeOS management guide.

Содержание 3642-0240

Страница 1: ...www westermo com Westermo Teleindustri AB User Guide 6642 22303 Industrial Ethernet SHDSL extender DDW 225 DDW 225 W O LV E R I N E S E R I E S WeOS...

Страница 2: ...ty or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of...

Страница 3: ...o fulfil the warranty obligations This unit must not be operating with removed covers or lids Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock or sha...

Страница 4: ...nce in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference...

Страница 5: ...ity No Title Issue EN 61000 6 1 Electromagnetic compatibility Immunity for residential environments 2007 EN 61000 6 2 Electromagnetic compatibility Immunity for industrial environments 2005 EN 61000 6...

Страница 6: ...N 61000 4 29 DC power ports 10 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage Radiated emission CISPR 16 2 3 ANSI C63 4 FCC part 15 Enclosure Class A and Class B...

Страница 7: ...tatus 3 IO Digital in Uin 60 VDC max Uin 10 mA max 4 IO Digital in M5 threaded hole for PE connection Position Direction descripton Input Output values 1 In out GND U 3 3 VDC max I 24 mA max 2 Out Tx...

Страница 8: ...of advanced diagnostic functions that allow the SHDSL line to be dynamically monitored allowing alarms to be configured to pre warn of any performance issues This monitoring data can be accessed in a...

Страница 9: ...polarity protected Redundant power input Yes Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required External supply current capab...

Страница 10: ...LV Maximum supply current 500 mA Isolation to All other except Console Galvanic connection to Console Connection USB receptacle connector type A Conductive housing Yes Connection to console port The c...

Страница 11: ...ocated close to rails Conductive housing Yes Number of ports 4 To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary or the cable is longer...

Страница 12: ...2 wire Receive Transmit SHDSL 2 In Out 2 wire Receive Transmit SHDSL Position Direction Description 1 2 3 4 1 Out Status 2 Out Status 3 In Digital in 4 In Digital in Direction relative this unit Posit...

Страница 13: ...cription 1 Out VBUS 2 In Out D 3 In Out D 4 Out GND Shield In Out Connected to PE Console see more information on page 14 Position Direction Description 1 In Out TD 2 In Out TD 3 In Out RD 4 Not conne...

Страница 14: ...ED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root switch VPN OFF VPN disabled GREEN Configurable Default At least on...

Страница 15: ...N rail TH 35 15 according to EN 60715 CLICK Wall mounting This unit can also be wall mounted see figure Earth connection For correct function the ground connection on the unit needs to be properly con...

Страница 16: ...the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Con...

Страница 17: ...o ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging one of the Ethernet cables T...

Страница 18: ...18 6642 22303...

Страница 19: ......

Страница 20: ...e North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co...

Отзывы: