Getting Started

This product runs Westermo Operating System (WeOS) which provides several  
management tools that can be used for configuration of the unit.

•  IPConfig tool  

This is a custom Westermo tool used for discovery of attached Westermo units.

• Web  

Configuration of the unit using the web browser. 

•  CLI

 

Configuration of the unit via the Command Line Interface.

If the computer is located in the same subnet as the switch you can easily use a web 
browser to configure the unit. Within the web you can configure most of the available 
functions. 
For advanced network settings and more diagnostic information, please use the CLI. 
Detailed documentation is available in the chapter 

The Command Line Management 

Tool

 in the WeOS management guide.

Factory default  

IP address:

 

192.168.2.200

 

Netmask:

 

255.255.255.0

 

Gateway:

 

Disabled

Note!

 If you are not sure about the subnet – consult your network administrator.

Configuration

Configure the unit via web browser 

The unit can easily be configured via a Web browser.  
Open the link http://192.168.2.200 in your web browser, and you will be prompted with  
a Login screen, where the default settings for Username and Password are:

Username:

 admin 

Password:

 westermo

Once you have logged in, you can use the extensive integrated help function describing 
all configuration options. Two common task when configuring a new switch is to assign 
appropriate IP settings, and to change the password of the admin account.  
The password can be up to 64 characters long, and should consist of printable ASCII 
characters (ASCII 33-126); 'Space' is not a valid password character.

Note!

 Version of IP Config tool must be 10.3.0 or higher.

Содержание 3642-0240

Страница 1: ...www westermo com Westermo Teleindustri AB User Guide 6642 22303 Industrial Ethernet SHDSL extender DDW 225 DDW 225 W O LV E R I N E S E R I E S WeOS...

Страница 2: ...ty or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of...

Страница 3: ...o fulfil the warranty obligations This unit must not be operating with removed covers or lids Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock or sha...

Страница 4: ...nce in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference...

Страница 5: ...ity No Title Issue EN 61000 6 1 Electromagnetic compatibility Immunity for residential environments 2007 EN 61000 6 2 Electromagnetic compatibility Immunity for industrial environments 2005 EN 61000 6...

Страница 6: ...N 61000 4 29 DC power ports 10 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage Radiated emission CISPR 16 2 3 ANSI C63 4 FCC part 15 Enclosure Class A and Class B...

Страница 7: ...tatus 3 IO Digital in Uin 60 VDC max Uin 10 mA max 4 IO Digital in M5 threaded hole for PE connection Position Direction descripton Input Output values 1 In out GND U 3 3 VDC max I 24 mA max 2 Out Tx...

Страница 8: ...of advanced diagnostic functions that allow the SHDSL line to be dynamically monitored allowing alarms to be configured to pre warn of any performance issues This monitoring data can be accessed in a...

Страница 9: ...polarity protected Redundant power input Yes Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required External supply current capab...

Страница 10: ...LV Maximum supply current 500 mA Isolation to All other except Console Galvanic connection to Console Connection USB receptacle connector type A Conductive housing Yes Connection to console port The c...

Страница 11: ...ocated close to rails Conductive housing Yes Number of ports 4 To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary or the cable is longer...

Страница 12: ...2 wire Receive Transmit SHDSL 2 In Out 2 wire Receive Transmit SHDSL Position Direction Description 1 2 3 4 1 Out Status 2 Out Status 3 In Digital in 4 In Digital in Direction relative this unit Posit...

Страница 13: ...cription 1 Out VBUS 2 In Out D 3 In Out D 4 Out GND Shield In Out Connected to PE Console see more information on page 14 Position Direction Description 1 In Out TD 2 In Out TD 3 In Out RD 4 Not conne...

Страница 14: ...ED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root switch VPN OFF VPN disabled GREEN Configurable Default At least on...

Страница 15: ...N rail TH 35 15 according to EN 60715 CLICK Wall mounting This unit can also be wall mounted see figure Earth connection For correct function the ground connection on the unit needs to be properly con...

Страница 16: ...the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Con...

Страница 17: ...o ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging one of the Ethernet cables T...

Страница 18: ...18 6642 22303...

Страница 19: ......

Страница 20: ...e North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co...

Отзывы: