5.2. Type Tests and Environmental Conditions
Environmental
phenomena
Basic
standard
Description
Test levels
ESD
EN 61000-4-2
Enclosure
Contact: ±6 kV
Air: ±8 kV
Fast transients
EN 61000-4-4
Power port
± 2 kV, 5 kHz, 100 kHz
Direct coupling
Earth port
I/O port
± 2 kV, 5 kHz, 100 kHz
Capacitive coupling clamp
Ethernet ports
Surge
EN 61000-4-5
Power port
L-E: ± 1 kV, 12
Ω
, 9 µF, 1.2/50 µs
L-E: ± 2 kV, 42
Ω
, 0.5 µF, 1.2/50 µs
L-L: ± 0,5 kV, 2
Ω
, 18 µF, 1.2/50 µs
L-L: ± 1 kV, 42
Ω
, 0,5 µF, 1.2/50 µs
I/O port
L-E: ± 2 kV, 42
Ω
, 0.5 µF, 1.2/50 µs
L-L: ± 1 kV, 42
Ω
, 0.5 µF, 1.2/50 µs
Ethernet ports
L-E: ± 2 kV, 2
Ω
, direct on shield, 1.2/50 µs
Power frequency
magnetic field
EN 61000-4-8
Enclosure
100 A/m, 16.7, 50 and 60 Hz
300 A/m DC
Pulsed magnetic field
EN 61000-4-9
Enclosure
300 A/m
Radiated RF
immunity
EN 61000-4-3
Enclosure
20 V/m, 80 MHz to 2,7 GHz
10 V/m, 2.7 to 6 GHz
Conducted RF
immunity
EN 61000-4-6
Power port
10 V, 80% AM, 1 kHz, 0.15 to 80 MHz
Spot frequencies: 2, 3, 4, 6.2, 8.2, 12.6, 16.5,
18.8, 22, 25 MHz
Earth port
I/O port
Ethernet ports
Radiated RF emission
CISPR 16-2-3
Enclosure
Class A (30 MHz to 6 GHz)
DNVGL-CG; Bridge and Deck Zone (0.15
to- 6 GHz)
Class A, FCC Part 15 B (30 MHz to 7
GHz)
ANSI C63,4
Conducted RF
emission
CISPR 16-2-1
Power port
Class A (0.15 to 30 MHz)
DNVGL-CG - Bridge and Deck Zone (0.01
to 30 MHz)
Class A, FCC Part 15 B (0.15 to 30 MHz)
ANSI C63.4
CISPR 22
Ethernet ports
Class A (0.15 to 30 MHz)
Compass safe
distance
IEC 60945
Enclosure
Minimum safe distance to:
standard compass: 15 cm
steering compass: 10 cm
Power supply failure
DNVGL-
CG-0339
Power port
U
N
-100%, 30 s
24
Lynx 3510 PoE