Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures
EN 60068-2-1
EN 60068-2-2
Operational
-40 to +70°C (-40 to +158°F) at
maximum 150 W PoE budget
-40 to +60°C (-40 to +140°F) at 240 W
PoE budget
-10 to +70 °C (14 to +158 °F) for CT-
models at 150 W PoE budget
-10 to +60 °C (14 to +140 °F) for CT-
models at 240 W PoE budget
Storage and
transport
-40 to +85 °C (-40 to +185 °F)
Humidity
EN 60068-2-30
Damp heat, cyclic
+25 to 55°C, 95% RH
2 cycles (12+12 hours) = 48 hours
Corrosive gases
IEC
60068-2-60
Operational
Method 3, 21 days
a
Altitude
Operational
2000 m/80 kPa
MTBF
Telcordia
638,000 hours
MTBF MIL-
HBDK-217F
583,000 hours
Vibration
b
IEC 60068-2-6
(sine)
Operational
5 to 8 Hz at ± 7.5 mm
8 to 500 Hz at 2 g
5 sweep cycles in each axis (3 x 5), 1
octave/min
IEC
60068-2-64
(random)
Operational
2.3 m/s
2
random, 5 to 2000 Hz, 3 x 1.5 h
Shock
IEC
60068-2-27
Operational
15 g/11 ms, 3 x 6 shocks
Enclosure
EN 61010-1
Aluminum
Fire enclosure
Weight
1100 gr
Degree of protection
EN 60529
Enclosure
IP40
Cooling
Convection
Overvoltage
category
EN/IEC
61010-1
OVC II
Pollution degree
EN/IEC
61010-1, EN
50124-1
PD2 macro and micro environment
Location
EN/IEC
61010-1
Indoor
a
Method 3, 21 days corresponds to Harsh Industrial Environment G3 which is defined in ANSI/ISA 17.04: 2015
b
The power and I/O cables need to be fastened 200 mm or closer to the unit. The same recommendation applies
to the Ethernet cables.
Table 7. Environmental and mechanical conditions
26