VHF-UHF Bi-Directional Amplifier Installation and Users Guide
System Operation: 5.4 BDA Alarms Page
WESTELL.COM
1-800-377-8766
Page 5-11
Once the user has opened an alarm’s popup display with the alarm settings and then
closed it, a single click will reopen it until the user navigates away from the BDA
Alarms page.
Details about each alarm indicator appears in
.
Table 5-3 Alarm Indicators
Alarm Display
Description
AC POWER
Loss of AC Power
BATTERY CAPACITY
Low battery capacity at 70% reduction
BATTERY CHARGER
Battery Disconnection or Battery Not Charging status
EMERGENCY POWER OFF
Emergency Power Off has been activated externally
DOWNLINK AMPLIFIER
Downlink high power amplifier shutdown
UPLINK AMPLIFIER
Uplink high power amplifier shutdown
DONOR ANTENNA
Donor ANT Disconnection/VSWR Fail/ Malfunction
DOOR OPEN
Door status check
OSCILLATION DETECTION
Oscillations detected, gain reduced
SYSTEM COMPONENT
Unspecified system component failure not identified by
another alarm
TEMPERATURE
Temperature is outside the set temperature range
REMOTE ANNUNCIATOR
LOSS OF COMMUNICATION
Annunciator loss of communication