3
1.2.1 Sonar On/Off Switch
The sonar on/off switch is fused with a 10
amp slow blow (MDL) fuse. This fuse is
inline with a fuse on the power supply board
inside the computer box. The power supply
fuse is 7.5 amp fast blow (AGC) for 12 or
24 volt operation.
1.2.2 Hoist Down/Up
To lower the hoist push down on the hoist switch.
If the hoist is hydraulic a green light will glow
when the motor is running and turn off when the
motor stops. The green light is not used with the
lead screw hoist systems. On all systems a red light
will stay on as long as the hoist is down.
1.2.3 Hoist Fuse
On lead screw hoist systems the fuse used is MDL
(slow blow) 3.2 amp. On hydraulic systems use
AGC (fast blow) 1 amp. If the fuse is open the
hoist will not go down.
1.3 Selection Screens
There are four selection screens where adjustments
are made. Each adjustment can be viewed as the
sonar runs to maximize target detection. The four
selection screens are titled as;
Wesmar 395, Sonar,
Profiler and Local
. To make an adjustment to the
sonar, trigger once with the hand controller. This
will activate the
Wesmar 395
selection screen. To
enter any of the other three selection screens push
up or down on the four way switch until SET UP
is highlighted. Push left or right on the four way
switch for:
S = Sonar, P = Profiler, L = Local
then
trigger with the hand controller. After adjustments
are made, trigger the hand controller to move the
cursor back to the sonar screen.
1.3.1 Wesmar 395 Selection Screen
Wesmar 395
is the first screen to appear when
triggered with the hand controller. All of the
adjustments are for sonar with the exception of
NEAR P and FAR P, which are gain adjustments
for profile.
Lead Screw Hoist
Hydraulic Hoist
Содержание SS395