background image

USING THE HYDROTHERAPY SPA

The hydrotherapy spa is designed to seat two adults.

The nine thera-jets can be regulated to provide a

relaxing massage to sooth away stress, and the

strength of the water massage can be adjusted by the

air control. The hydrotherapy spa holds 200 gallons

(167 imperial gallons) of water and offers an automat-

ic, programmable heating (80°F to 104°F [21°C to

40°C]) and filtration system.

The guidelines below explain how to properly use the

hydrotherapy spa. Follow these guidelines to maintain

the hydrotherapy spa for your long-term enjoyment.

PLUGGING IN THE HYDROTHERAPY SPA

Important: The hydrotherapy spa is equipped with a

120/240V convertible electronics package. Operation

at 240V will allow the heater to run more efficiently

and less often.

Conversion of the spa to 240V oper-

ation must be performed only by a qualified,

licensed electrician and must comply with all

local, state, and federal electrical codes.

Please

refer to the instructions on the inside of the electronics

package for information about converting the spa to

240V operation.

Once the hydrotherapy spa is filled with water, the

power cord can be plugged in and the spa can be

turned on. Note: The first time the power cord is

plugged in, the spa will turn on automatically.

When connecting the power cord, plug the power cord

directly into a grounded circuit capable of carrying 15

or more amps. No other appliance should be on the

same circuit. Replace the power cord immediately if it

becomes damaged.

There is a Ground

Fault Circuit

Interrupter (GFCI)

on the end of the

power cord. Always

test the GFCI

before using the

hydrotherapy spa.

First, turn on the

spa by pressing the

jet control on the

console (see USING THE CONSOLE on page 13).

Once the unit is running, press the GFCI “test” button.

The spa should shut off. Press the “reset” button. The

spa should resume normal operation. If the spa contin-

ues to run after the “test” button is pressed, the GFCI is

damaged. Do not use the spa until the GFCI has been

repaired or replaced by a qualified electrician.

TESTING AND TREATING THE WATER

The first time you use the spa, you should test and

treat the water.

You must also treat the water each

time you refill the spa.

A test strip and a chemical

pack are available at your local pool and spa store.

Follow the directions carefully on the chemical pack to

test and treat the water.

Always keep the chemicals

away from children and pets.

See WATER CHEMISTRY on page 13 for information

concerning proper water maintenance.

STARTING THE HYDROTHERAPY SPA

Once you have tested the GFCI, you should verify the

water flow from the pumping unit. Set the air control

on the console to the lowest setting (see CONSOLE

DIAGRAM on page 13). The pumping unit will heat

the water as it pumps. Cover the hydrotherapy spa

with the spa cover.

The spa cover must be tight.

(See SECURING THE SPA COVER on page 14.) The

water will heat at about 2.0°F (1°C) an hour with the

cover on. If you are using the spa indoors, and the

room temperature is maintained at 70°F (21°C), it will

take approximately 24 to 26 hours for the water to

reach the set temperature.

The temperature and water flow can be set or

changed by the controls on the console (see CON-

SOLE DIAGRAM on page 13).

Test and

Reset

Buttons

Grounded

circuit capable

of carrying 15 or

more amps

GFCI

11

Содержание Daybreak 510

Страница 1: ...gh direct assistance from our factory TO AVOID UNNECESSARY DELAYS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis t...

Страница 2: ...TANT SAFETY INSTRUCTIONS 4 BEFORE YOU BEGIN 7 CHOOSING A LOCATION FOR THE HYDROTHERAPY SPA 8 SETUP AND ASSEMBLY 9 USING THE HYDROTHERAPY SPA 11 MAINTENANCE 15 TROUBLE SHOOTING 19 PART LIST 22 EXPLODED...

Страница 3: ...eratures or damage to the spa shell resulting from exposure to direct sunlight and ultraviolet rays while the spa is empty damage to the pump motor plumbing and compo nents due to improper maintenance...

Страница 4: ...spa shell can reach temperatures as high as 150 F in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blistering of the shell s...

Страница 5: ...Children must always be super vised 28 DANGER To reduce the risk of drowning Never use the hydrotherapy spa alone Children should not use the spa unless they are supervised by an adult Keep pets away...

Страница 6: ...To reduce the risk of injury It is especially important for persons over the age of 35 or persons with pre existing health problems such as obesity heart disease high or low blood pressure circulator...

Страница 7: ...ed treatment you need to feel your best For your safety and benefit read this manual care fully before using the DAYBREAK 510 If you have additional questions please call our Customer Service Departme...

Страница 8: ...eck system that is built flush with the top of the spa provided you leave access to the motor for ser vice 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may af...

Страница 9: ...he information on the previous two pages Remove the four cover screws from the access cover Remove the access cover from the spa unit by sliding the access cover down and pulling the bottom of the acc...

Страница 10: ...8 over the spa Be sure that the Spa Cover is properly centered Snap a Buckle 2 onto each of the four latches on the Spa Cover 18 See the inset drawing Position one of the Buckles 2 on the wood panels...

Страница 11: ...nd of the power cord Always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet control on the console see USING THE CONSOLE on page 13 Once the unit is running p...

Страница 12: ...e on your lower or middle back The remain ing jet located on the other bench seat focuses a water massage on your upper or lower back The filter C can be removed for replacement and cleaning see page...

Страница 13: ...ther accurate ther mometer to check the temperature of the water Note The word COOL will appear in the console display if the temperature of the water is more than 20 F cooler than the set temperature...

Страница 14: ...in use Keep the keys in a safe place out of the reach of children ATTACHING THE RED AND BLUE LIGHT COVERS The hydrotherapy spa includes red and blue light covers for the spa light To attach one of th...

Страница 15: ...vice on which sealants work best in your climate CLEANING THE SPA SHELL The spa shell should be cleaned with a mild soap solution Do not use solvents The spa should always be clean and dry before bein...

Страница 16: ...oad temperature and water conditions Proper water maintenance is a com plex process Contact your local pool and spa supplier for information concerning which chemicals you should use in your area to s...

Страница 17: ...e spa and treat the water with chemicals see pages 15 and 16 DRAINING THE PUMP After the hydrotherapy spa is drained see DRAINING THE HYDROTHERAPY SPA the pump in the spa jet unit should also be drain...

Страница 18: ...our above to remove the basket 2 Reach into the housing and turn the valve on the diverter until it is fully open 3 Stick two fingers into the holes in the diverter and lift the diverter and the top f...

Страница 19: ...rranty you may also con tact a local spa and pool service provider 6 SYMPTOM THE WATER DOES NOT HEAT a Make sure that the hydrotherapy spa is fully covered with the spa cover The spa cover must be tig...

Страница 20: ...rt ment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing If you can identify the location of the leak inside the spa jet unit tight en the...

Страница 21: ...21 NOTES...

Страница 22: ...1 Control Unit 15 4 Lock Washer 16 2 Heater Gasket 17 1 Air Control Knob 18 1 Spa Cover 19 1 Red Lens 20 3 Multidirectional Jet 21 1 Diverter 22 1 Basket 23 10 8 x 1 1 2 Screw 24 1 Filter Door 25 2 C...

Страница 23: ...23 4 28 5 13 29 12 3 14 9 16 16 3 9 15 8 1 2 2 7 17 18 26 25 20 20 31 20 27 EXPLODED DRAWING Model No WLSB40070 WLSG40070 or WLSG51020 R0202A...

Страница 24: ...following information when calling 1 The MODEL NUMBER of the product WLSB40070 WLSG40070 or WLSG51020 2 The NAME of the product WESLO DAYBREAK 510 3 The SERIAL NUMBER of the product see the front cove...

Отзывы: