background image

5

20. Do not use an extension cord with the

hydrotherapy spa. This could damage the

motor and will void the warranty.

21. DANGER—If you will be using the hydrother-

apy spa outside, do not bury the power cord.

Keep the power cord away from lawn mowers,

hedge trimmers, and other similar equipment.

22. WARNING—The power cord is equipped with

a Ground Fault Circuit Interrupter (GFCI),

located at the end of the power cord. The

GFCI must be tested before each use. To test

the GFCI, press the “test” button while the

hydrotherapy spa is running. The spa should

shut off. Press the “reset” button. The spa

should resume normal operation. If the spa

continues to run after the “test” button is

pressed, then the GFCI is damaged. Do not

use the spa until the GFCI has been repaired

or replaced by a qualified electrician.

23. Keep all electrical appliances such as radios,

telephones, televisions, and lights at least

five feet (1.52 meters) away from the water.

24. A wire connector is provided on the pump

motor of this unit to connect a minimum No.

8 AWG (8.04 mm

2

) solid copper conductor

between this unit and any metal equipment,

electrical enclosure made of metal, metal

water pipes, or conduit within five feet

(1.52m) of the unit.

25. DANGER—Risk of electric shock: Do not set

up the hydrotherapy spa within five feet of

any metal objects or surfaces. As an alterna-

tive, you may use the spa within five feet of

metal objects if each metal object is perma-

nently connected to the wire connector on

the pump motor of this unit by a minimum

No. 8 AWG (8.04 mm

2

) solid copper conduc-

tor (see instruction 24).

26. Do not operate the pump motor when the

hydrotherapy spa is empty. The pump motor

may be seriously damaged if it is operated

without water circulating.

27. DANGER—Risk of drowning: Exercise

extreme caution to prevent unauthorized and

unsupervised use of the hydrotherapy spa by

children. Children must always be super-

vised.

28. DANGER—To reduce the risk of drowning:

• Never use the hydrotherapy spa alone;

• Children should not use the spa unless

they are supervised by an adult;

• Keep pets away from the spa at all times;

• Always replace and lock the spa cover

when the spa is not in use.

29. WARNING—To reduce the risk of injury: The

water temperature should never exceed

104°F (40°C). Temperatures between 100°F

(38°C) and 104°F (40°C) are considered to be

safe for healthy adults. However, if you plan

to remain in the hydrotherapy spa for more

than 10 to 15 minutes, a lower temperature is

recommended. Lower temperatures are also

recommended for children. Children should

not be allowed to swim under the surface of

the water in the spa.

30. WARNING—To reduce the risk of injury:

Always use an accurate thermometer to

determine the water temperature before

using the hydrotherapy spa.

31. WARNING—To reduce the risk of injury:

Pregnant women should consult with their

physician before using the hydrotherapy spa.

Pregnant women should not use the

hydrotherapy spa if the water temperature is

above 100°F (38°C); the unborn child could

be seriously harmed. This is especially

important during the first 90 days of the

pregnancy.

32. DANGER—To reduce the risk of drowning:

Prolonged immersion in the hydrotherapy

spa may cause hyperthermia, a dangerous

condition which occurs when the internal

body temperature rises several degrees

above the normal body temperature of 98.6°F.

The symptoms of hyperthermia are nausea,

dizziness, drowsiness, and fainting. Effects

include: a lack of awareness, inability to per-

ceive heat or danger, and a greater risk of

drowning due to a loss of consciousness.

Special note: Individuals suffering from

hyperthermia may be unable to realize that

they must exit the hydrotherapy spa, and

they also may be physically unable to do so.

33. WARNING—To reduce the risk of drowning:

Do not use the hydrotherapy spa if you are

under the influence of alcohol or drugs. Heat

from the water, in conjunction with alcohol or

drugs can cause unconsciousness.

Содержание Daybreak 510

Страница 1: ...gh direct assistance from our factory TO AVOID UNNECESSARY DELAYS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis t...

Страница 2: ...TANT SAFETY INSTRUCTIONS 4 BEFORE YOU BEGIN 7 CHOOSING A LOCATION FOR THE HYDROTHERAPY SPA 8 SETUP AND ASSEMBLY 9 USING THE HYDROTHERAPY SPA 11 MAINTENANCE 15 TROUBLE SHOOTING 19 PART LIST 22 EXPLODED...

Страница 3: ...eratures or damage to the spa shell resulting from exposure to direct sunlight and ultraviolet rays while the spa is empty damage to the pump motor plumbing and compo nents due to improper maintenance...

Страница 4: ...spa shell can reach temperatures as high as 150 F in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blistering of the shell s...

Страница 5: ...Children must always be super vised 28 DANGER To reduce the risk of drowning Never use the hydrotherapy spa alone Children should not use the spa unless they are supervised by an adult Keep pets away...

Страница 6: ...To reduce the risk of injury It is especially important for persons over the age of 35 or persons with pre existing health problems such as obesity heart disease high or low blood pressure circulator...

Страница 7: ...ed treatment you need to feel your best For your safety and benefit read this manual care fully before using the DAYBREAK 510 If you have additional questions please call our Customer Service Departme...

Страница 8: ...eck system that is built flush with the top of the spa provided you leave access to the motor for ser vice 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may af...

Страница 9: ...he information on the previous two pages Remove the four cover screws from the access cover Remove the access cover from the spa unit by sliding the access cover down and pulling the bottom of the acc...

Страница 10: ...8 over the spa Be sure that the Spa Cover is properly centered Snap a Buckle 2 onto each of the four latches on the Spa Cover 18 See the inset drawing Position one of the Buckles 2 on the wood panels...

Страница 11: ...nd of the power cord Always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet control on the console see USING THE CONSOLE on page 13 Once the unit is running p...

Страница 12: ...e on your lower or middle back The remain ing jet located on the other bench seat focuses a water massage on your upper or lower back The filter C can be removed for replacement and cleaning see page...

Страница 13: ...ther accurate ther mometer to check the temperature of the water Note The word COOL will appear in the console display if the temperature of the water is more than 20 F cooler than the set temperature...

Страница 14: ...in use Keep the keys in a safe place out of the reach of children ATTACHING THE RED AND BLUE LIGHT COVERS The hydrotherapy spa includes red and blue light covers for the spa light To attach one of th...

Страница 15: ...vice on which sealants work best in your climate CLEANING THE SPA SHELL The spa shell should be cleaned with a mild soap solution Do not use solvents The spa should always be clean and dry before bein...

Страница 16: ...oad temperature and water conditions Proper water maintenance is a com plex process Contact your local pool and spa supplier for information concerning which chemicals you should use in your area to s...

Страница 17: ...e spa and treat the water with chemicals see pages 15 and 16 DRAINING THE PUMP After the hydrotherapy spa is drained see DRAINING THE HYDROTHERAPY SPA the pump in the spa jet unit should also be drain...

Страница 18: ...our above to remove the basket 2 Reach into the housing and turn the valve on the diverter until it is fully open 3 Stick two fingers into the holes in the diverter and lift the diverter and the top f...

Страница 19: ...rranty you may also con tact a local spa and pool service provider 6 SYMPTOM THE WATER DOES NOT HEAT a Make sure that the hydrotherapy spa is fully covered with the spa cover The spa cover must be tig...

Страница 20: ...rt ment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing If you can identify the location of the leak inside the spa jet unit tight en the...

Страница 21: ...21 NOTES...

Страница 22: ...1 Control Unit 15 4 Lock Washer 16 2 Heater Gasket 17 1 Air Control Knob 18 1 Spa Cover 19 1 Red Lens 20 3 Multidirectional Jet 21 1 Diverter 22 1 Basket 23 10 8 x 1 1 2 Screw 24 1 Filter Door 25 2 C...

Страница 23: ...23 4 28 5 13 29 12 3 14 9 16 16 3 9 15 8 1 2 2 7 17 18 26 25 20 20 31 20 27 EXPLODED DRAWING Model No WLSB40070 WLSG40070 or WLSG51020 R0202A...

Страница 24: ...following information when calling 1 The MODEL NUMBER of the product WLSB40070 WLSG40070 or WLSG51020 2 The NAME of the product WESLO DAYBREAK 510 3 The SERIAL NUMBER of the product see the front cove...

Отзывы: