![Werner & Weber MPC-A Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/werner-and-weber/mpc-a/mpc-a_operation-manual_957248012.webp)
3. OPERATION / HANDLING
3.1. INSTALLATION INSTRUCTIONS
DANGER
Read and follow these and the safety instructions of chapter 1 !
1. Note the following safe-floor loads:
a. for skip units not less than 13.000 N/m 2 ,
b. for roll on/off units not less than 17.000 N/m 2 .
2. Provide sufficient space at the installation site for transportation with the skip unit or roll on/off unit.
3. If charging of the waste compactor is done from a loading dock or platform(s), make sure that the
hopper is at least 1 m above ramp height (i.e. operator´s location)!
4. Note that the floor for installation of the compactor should be even.
5. If required, provide additional lighting at the installation site (in accordance with AAV).
6. Protect installation site against accessing by unauthorized personnel.
7. Note that the power supply at the installation site must be protected by means of a safety switch
(with a sensitivity of 30mA) and a 16A fuse.
8. The supply cable must have a cross-section of 5 x 2.5 mm 2 and should be fitted with a
16A CEE-standard socket.
9. Movable supply cables require a solid (rubber) hose pipe of the type HO
/
RN-F according to
VDE 0100.