5
INST-EZG-D
OPERATING PRECAUTIONS
EZG-SERIES
Created: 7/22/13
Document:
Page 5 OF 10
INST-EZG-D
OPERATING PRECAUTIONS
DO NOT IMPROPERLY USE GRIP
This EZG is designed to grab objects and debris and not for any other use.
BE AWARE OF SURROUNDING UTILITIES
Operator must be aware of all utility line and overhead electrical lines. Operations must be
able to clear all lines safely.
BE AWARE OF OVERHEAD DANGER
Operator must be aware of all possible overhead dangers that are within the range of motion of
the operating machine.
DO NOT OPERATE WITH A LOOSE ATTACHMENT
Visually check the coupler to verify attachments are secure and lock is fully engaged and that
the center to center of the attachment matches the up with the coupler.
PINCH POINTS
Personal injury could result from the careless misuse of this coupler. Keep hands and body
parts clear of the coupler when it’s in the process of hooking up to an attachment. Be sure the
machine is off and the attachment is on the ground prior to making adjustments.
WELDING INSTRUCTIONS
All Welding to be done by a Certified Welder!
Dipper Mounting Bracket & Return Stop
a.) Disconnect battery before welding.
b.) Use a low hydrogen electrode.
c.) Clean weld area – weld completely around bracket.
d.) Weld a 3/8 fillet on the sides of the bracket to the stick.
NOTE: Some models include side plates which transfer the loads onto the
stick. See the enclosed illustrations for these models (Case 580 D & E, and all
Extend-a-hoes). The Case 580K,L,& N requires a special mount due to dipper
material. See the enclosed instructions for the installation of this mount.
DO NOT WELD ANYTHING INPLACE BEFORE CHECKING ROTATION
AND CLEARANCES!!!!
Components List
See separate parts breakdown
Содержание EZG Series
Страница 11: ......