High Performance Distance Sensors
5. Mounting Instructions
All applicable electrical and mechanical regulations, standards and safety precautions must be adhered to
when installing and operating the Sensor. The Sensor must be protected against mechanical influences. Install
the device such that its installation position cannot be inadvertently changed. The wenglor mounting system is
recommended for installing the Sensor. Additionally a suiting reflector or reflex foil has to be mounted.
6. Initial Start-Up
6.1. Initial Start-Up
Connect the Sensor to supply power (18 to 30 V DC). The display view appears.
The Sensor is ready for operation after 2 seconds. The following table provides an overview of typical, addi-
tional deviations during the warm-up phase.
Time (min.)
0
1
2
5
10
15
Deviation (mm)
±10
±7
±6
±2
±1
0
Switch to the configuration menu by pressing any key.
Note:
If no settings are adjusted in the configuration menu for a period of 30 s, the Sensor is automatically returned to
the read-out view. The Sensor accesses the last used menu view when a key is once again activated.
If a setting is adjusted, it becomes active when the configuration menu is exited.
The keys are used for navigation, and for configuring settings.