30
Setup via IO-Link
Function
Possible Settings
Default
Window Teach-In
Object
Sensor
Near switching point
Far switching point
Window size
NOTE!
The far switching point must be greater than the near
switching point.
Switching point
100…1200 mm
1200 mm
Near switching
point window
100…1200 mm
100 mm
Far switching
point window
100…1200 mm
100 mm
Additional
hysteresis
0…500 mm
The hysteresis is the difference between the switch-on and switch-off
point.
The sensor has a minimum hysteresis of 1% of the switching distance,
but at least 2 mm. This cannot be changed. An additional hysteresis in
mm can be set for each switching point.
The total hysteresis is calculated from internal switching hysteresis (1%)
+ additional hysteresis.
The sum of the switching point, hysteresis and additional hysteresis
must not exceed the maximum measuring range of the sensor.
0 mm