28
Setup via IO-Link
I3
Transmit Signal Off Input
The sensor’s transmit signal is deactivated as long as the input is acti-
vated. The sensor does not send a measured value and sets the status
to "No signal".
Teach-In Input
Teach-in
The outputs (switching outputs) can be set using the same procedure
as with the teach-in key (see section 6). An activated input corresponds
to a depressed teach-in key.
Locking
If 18…30 V DC is continuously applied to the teach-in input, the teach-in
key is locked and protected against inadvertent changes, like the input
signal.
Synchronous Input/Output
The input is used for communication between the Synchronous Master
Unit and the Synchronous Sub Unit.
Deactivated
The pin is deactivated.
Transmit signal
off input
8.1.2.2 Output Functions
The output functions are used to set the physical outputs.
Function
Possible Settings
Default
PNP/NPN/
Push-Pull
PNP
NPN
Push-Pull
PNP
NC/NO
NO
Light switching (normally open)
The output is high when the condition has been fulfilled depending on
the setting (switching point, warning, error).
NC
Dark switching (normally closed)
The output is low when the condition has been fulfilled depending on
the setting (switching point, warning, error).
NO
On-
delay
0…10,000 ms
0 ms
Off-delay
0…10,000 ms
0 ms