EN
44
Condensed Start-Up Instructions
8. Condensed Start-Up Instructions
Start
Set all DIP
switches to off
Align the light
barrier mechanically
Press and hold the
enter key on the
receiver for 1 s
Do the
blanking alignment
and failure LEDs
blink?
Alignment degree
appears at the
display
99 – very good
44 – not good
43 – rays masked
see table “Degree of alignment
against the distance between
transmitter and receiver”
Press and hold the
enter key on the
receiver for 1 s
The receiver boots and
activates the outputs
The Safety Light
Array is ready for
operation
yes
Improve
alignment
no
Is
restart inhibit
required?
Is contactor
monitoring
required?
Set the restart
inhibit DIP switch
Set the contactor
monitoring DIP switch
yes
yes
…
Distance transmitter – receiver
Without tilted mirror
With 1 tilted mirror
With 2 tilted mirrors
Degree of alignment
≤
3 m
≤
2,7 m
≤
2,4 m
96 imperatively necessary
3...20 m
2,7...18 m
2,4...16 m
96, 78, 68, 56 preferred
> 43 necessary