35
Controller for Through Beam Sensors
Cascading
• Disconnect the power supply
• Cascade the control units (see page 31)
• Turn the rotary selector switch
to position 1...9 at ONE of the control units
è
Master
• Turn the rotary selector switch
to position 10 at ALL OTHER control units
è
Slaves
• Connect the master to power supply. The slaves are supplied with power from the bus terminal at the master.
è
The control panels at the slaves are disabled (switch position 10)
è
The control panel at the master remains active (switch in RUN position), and the master
functions are imposed upon the slaves
Master
Slave