USING YOUR GENERATOR
CIRCUIT BREAKERS
In addition to the reset button that protects the generator’s main
circuit, the circuit breakers (Fig. 16) protect the individual AC and
DC circuits. The 20-amp AC circuit breaker will activate when the
NEMA 5-20 outlets exceed 20A. The 10-amp DC circuit breaker
will activate when the DC 12V and USB outlets exceed 10A. When
the circuit breaker activates, turn off and disconnect the device
from its respective outlet, and press the circuit breaker to reset.
Fig. 16
DATA METER
The Data Meter on your generator switches between voltage (e.g. 120.1), frequency (e.g. 60.0H), and runtime (e.g.
12.3) every 5 seconds. When you first use the generator, the meter will count runtime, but will not store runtime
until the generator is run for longer than 2 hours at a time. Once the generator has been run for more than 2 hours
at a time, the meter will track runtime normally. For an example, as well as more explanation, please refer to the
chart below.
SESSION
NUMBER
SESSION
LENGTH
HOUR METER
AT END OF SESSION
DOES THE
METER RESET?
COMMENTS
1
1 hr 30
min
1.5
Yes, to 0.0
Meter will show “1.5” just before it is shut
off, but it has not been run for 2 hours at
a time yet.
2
30 min
0.5
Yes, to 0.0
Meter will show “0.5” just before it is shut
off, but it has not been run for 2 hours at
a time yet.
3
1 hr
1
Yes, to 0.0
Meter will show “1.0” just before it is shut
off, but it has not been run for 2 hours at
a time yet.
4
3 hr
3
No
Meter will show “3.0” at the end, since it
has been run for more than 2 hours. It will
not include the 3 hours (1.5 + 0.5 + 1) the
generator was run before.
5
2 hr
5
No
Meter will show “5.0” at the end, since it
has been run for 3 + 2 = 5 hours. The me-
ter is counting normally, and will continue
operating normally.
Every 50 hours, the meter will display “]--[“, which is to remind you to perform 50-hour maintenance. Consult the
maintenance chart for recommended procedures. The display code will appear every 15 seconds for 6 minutes.
After 6 minutes, or after the generator is shut down and restarted, the code will clear and display voltage, frequency,
and runtime, as before.