SELF-DIAGNOSTIC ALARM CODES

Alarm Display

Problem

Cause

Corrective Action

Frost prevention

sensor and Abnormal

temperature sensor 

value

•  Indoor heat 

exchanger tempera

-

ture too low

•  TH3 temperature 

sensor  has a loose 

or broken connec

-

tion

•   Do not use the air 

conditioner if ambient 

temperature is lower 

than 18°C (64°F)

•  Contact a qualified 

service agent

Refrigerant high

pressure switch

• Blocked air filter

•  Blocked / kinked 

exhaust duct

•  Ambient tempera

-

ture is too high

• Clean air filter

•  Ensure exhaust duct is 

not blocked / kinked

•  Do not use the air 

conditioner if ambient 

temperature is higher 

than 45°C (113°F)

Abnormal tempera

-

ture sensor value

TH1(Outlet) tem

-

perature sensor has 

a loose or broken 

connection

Contact a qualified service 

agent

Abnormal tempera

-

ture sensor value

TH2(Inlet) tem

-

perature sensor has a 

loose or

broken connection

Contact a qualified service 

agent

Compressor over

-

loaded

•  Ambient tempera

-

ture is too high

•  Unstable voltage 

supply

•  Defective compres

-

sor

•  Do not use the air 

conditioner if ambient 

temperature is higher 

than 45°C (113°F)

•  Contact a qualified 

service agent

• Replace compressor

Condensate water 

level alarm

Condensate tank is full

•  Empty the water tank

•  After installation of the 

water tank, press the 

SPOT/COOL or ROOM/

COOL button to resume 

operation

Drain pump alarm

Drain pump defective 

or improper hose con

-

nection (including kink 

or blockage)

•  Check the aconnection 

and hose

• Replace drain pump

Table 1- Alarm Codes

Содержание WPC-4000

Страница 1: ...owing operating modes room and set temperatures and faults If an abnormal operation oc curs a visual display of the fault is shown Caster wheels are included for easy portability Suitableapplicationsi...

Страница 2: ...irst use 2 Always place the unit on an even level surface 3 Ensure the unit is connected to a grounded power supply of the correct rating capacity 4 The unit will cool when the room temperature is bet...

Страница 3: ...able environments DO NOT operate a unit with a damaged power cord 19 The filters must be used with the product at all times When the filters are removed for clean ing always ensure that the unit has b...

Страница 4: ...d inside of box with cool air outlet hose s to install the cool air outlet hose s on the air condi oner as shown in Figure 6 POWER CORD HOLDER DISCHARGE DUCTS SUPPLY AIR DUCT Figure 3 Figure 2 Figure...

Страница 5: ...ngs NOTE Make sure the AC outlet is free of dirt dust oil water or any other foreign material WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or in ar...

Страница 6: ...links and indicates abnormal system operation If Alarm oc curs compressor stops System operation stops when ALARM light is activated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room t...

Страница 7: ...in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of filter into the guide and let filter gently fall inside the guide NOTE For effective coolin...

Страница 8: ...ccurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will con tinue to run for 3 minutes If the fault is rectified within 3...

Страница 9: ...rmal tempera ture sensor value TH1 Outlet tem perature sensor has a loose or broken connection Contact a qualified service agent Abnormal tempera ture sensor value TH2 Inlet tem perature sensor has a...

Страница 10: ...10 Owner s Manual WPC 4000 Wiring Diagram Figure 12 Circuit Wiring Diagram WPC 4000 DRAIN PUMP option...

Страница 11: ...if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before turning the uni...

Страница 12: ...installation or use of products Product Suitability Many jurisdictions have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary f...

Отзывы: