Owner’s Manual

WPC-4000

Maintenance

FILTER CLEANING 

(See Figures 9 and 10)

There are two filters in the unit.  The evaporator filter is located at the front of the unit. The 

condenser filter is located at the side of the unit.
1. loosen up 2 bolts on the front filter guard.
2. Slide filter up and use a vacuum cleaner to remove the dust from the filter.
3.  If the filter is heavily covered with dust and dirt, warm water and mild soap or neutral deter

-

gent may be used to wash the filter. Do not use any other chemicals to clean filter, as they will 

likely damage the filter.

4.  Dry the filter in a shaded area before replacing it. Do not operate the unit without the filter 

installed and the filter guard in the closed position.

5. Replace the clean filter and close the filter guard.
6.  To clean the condenser filter, lift up on the side filter from the middle bar slightly and then 

angle the filter outwards from the bottom and remove.

7.Use the same cleaning procedure as above (3 – 5).
8.  To replace the condenser filter, place the top of the filter in the guide and slide the filter up 

until the bottom of the filter clears the frame. Then push the bottom of filter into the guide 

and let filter gently fall inside the guide.

NOTE: For effective cooling clean the filter at least every 2 weeks.

–   For your convenience, record the complete model number and product name (located on the 

Product Identification Plate), the purchase date, purchase location, serial number, and war

-

ranty period in the table below.

–   Also, attach your purchase receipt as proof of purchase to this instruction manual for future 

reference.

–   To ensure your product is covered by warranty, the complete faulty product along with your 

original purchase receipt must be provided at the place of purchase.

Do not operate without the filter fitted.
Do not operate the unit with a damaged cord or plug, after the unit malfunc-

tions, or if the unit has been dropped or damaged.

– Loosen up 2 bolts on
   the front filter guard.

– Slide filter up and use
   a vacuum cleaner to remove
   the dust from the filter.

– Remove dust from the filter
   using a vacuum cleaner
   hose aachment. 
– If required wash the filter in
   lukewarm water with a mild
   detergent. Leave to dry in
   a shaded area before
   reinstalling.

Figure 9 – Removing Filters

Figure 10 – Removal of Dust

Содержание WPC-4000

Страница 1: ...owing operating modes room and set temperatures and faults If an abnormal operation oc curs a visual display of the fault is shown Caster wheels are included for easy portability Suitableapplicationsi...

Страница 2: ...irst use 2 Always place the unit on an even level surface 3 Ensure the unit is connected to a grounded power supply of the correct rating capacity 4 The unit will cool when the room temperature is bet...

Страница 3: ...able environments DO NOT operate a unit with a damaged power cord 19 The filters must be used with the product at all times When the filters are removed for clean ing always ensure that the unit has b...

Страница 4: ...d inside of box with cool air outlet hose s to install the cool air outlet hose s on the air condi oner as shown in Figure 6 POWER CORD HOLDER DISCHARGE DUCTS SUPPLY AIR DUCT Figure 3 Figure 2 Figure...

Страница 5: ...ngs NOTE Make sure the AC outlet is free of dirt dust oil water or any other foreign material WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or in ar...

Страница 6: ...links and indicates abnormal system operation If Alarm oc curs compressor stops System operation stops when ALARM light is activated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room t...

Страница 7: ...in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of filter into the guide and let filter gently fall inside the guide NOTE For effective coolin...

Страница 8: ...ccurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will con tinue to run for 3 minutes If the fault is rectified within 3...

Страница 9: ...rmal tempera ture sensor value TH1 Outlet tem perature sensor has a loose or broken connection Contact a qualified service agent Abnormal tempera ture sensor value TH2 Inlet tem perature sensor has a...

Страница 10: ...10 Owner s Manual WPC 4000 Wiring Diagram Figure 12 Circuit Wiring Diagram WPC 4000 DRAIN PUMP option...

Страница 11: ...if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before turning the uni...

Страница 12: ...installation or use of products Product Suitability Many jurisdictions have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary f...

Отзывы: