Weltem WPC-4000 Скачать руководство пользователя страница 4

4

5

Owner’s Manual

WPC-4000

Assembly (WPC-4000)

COMPONENT PARTS

Cool air outlet hose

Front and Right Side View

Display / Control board

Top fan exhaust flange

Evaporator / filter

Guide bar for condensate water tank

Condensate water tank (Water level is

sensed, and the unit opera­on is stopped

when tank is full. An alarm will be

displayed. Empty the tank and replace to

resume opera­on)

1. Take out the cord holder from

    the accessory box.

2. Place the cord holder on the

    back side of air condi­oner.

3. Use screws (enclosed inside

    of accessory box with cord holder)

    to install the cord holder on the

    air condi­oner as shown in Figure 4.

1. Remove cool air outlet hose(s) from carton.

2. Place the cool air outlet hose(s) on the front top of air condi­oner.

3. Use screws (enclosed inside of box  with cool air outlet hose(s) to install 

    the cool air outlet hose(s) on the air condi­oner as shown in Figure 6.

POWER CORD HOLDER

DISCHARGE DUCTS/SUPPLY AIR DUCT

Figure 3

Figure 2

Figure 4

Figure 6

Back and Le‘ Side View

Condenser / filter

Power cord holder
Caster

Electrical access panel

1. Remove the top fan exhaust

    flange from carton.

2. Place the top fan exhaust flange

    on the top of air condi­oner.

3. Use screws (enclosed inside

    of box with the top fan exhaust

    flange) to install the top fan

    exhaust flange on air condi­oner

    as shown in Figure 5.

TOP FAN EXHAUST FLANGE

Figure 5

Figure 7

A

B

C

An ambient air adapter can be purchased separately. Air adapter 

fits over the condenser to duct condenser air to the unit to improve 

cooling efficiency.

1. Remove the Filter("A")

2. Check the Filter("C") is inserted properly in Intake Warm Air Duct("B")

3. Install "B" which contains "C" by using driver with enclosed

     bolts(6EA) as Figure 7.

AMBIENT AIR ADAPTER 

(Op…onal)

Содержание WPC-4000

Страница 1: ...owing operating modes room and set temperatures and faults If an abnormal operation oc curs a visual display of the fault is shown Caster wheels are included for easy portability Suitableapplicationsi...

Страница 2: ...irst use 2 Always place the unit on an even level surface 3 Ensure the unit is connected to a grounded power supply of the correct rating capacity 4 The unit will cool when the room temperature is bet...

Страница 3: ...able environments DO NOT operate a unit with a damaged power cord 19 The filters must be used with the product at all times When the filters are removed for clean ing always ensure that the unit has b...

Страница 4: ...d inside of box with cool air outlet hose s to install the cool air outlet hose s on the air condi oner as shown in Figure 6 POWER CORD HOLDER DISCHARGE DUCTS SUPPLY AIR DUCT Figure 3 Figure 2 Figure...

Страница 5: ...ngs NOTE Make sure the AC outlet is free of dirt dust oil water or any other foreign material WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or in ar...

Страница 6: ...links and indicates abnormal system operation If Alarm oc curs compressor stops System operation stops when ALARM light is activated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room t...

Страница 7: ...in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of filter into the guide and let filter gently fall inside the guide NOTE For effective coolin...

Страница 8: ...ccurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will con tinue to run for 3 minutes If the fault is rectified within 3...

Страница 9: ...rmal tempera ture sensor value TH1 Outlet tem perature sensor has a loose or broken connection Contact a qualified service agent Abnormal tempera ture sensor value TH2 Inlet tem perature sensor has a...

Страница 10: ...10 Owner s Manual WPC 4000 Wiring Diagram Figure 12 Circuit Wiring Diagram WPC 4000 DRAIN PUMP option...

Страница 11: ...if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before turning the uni...

Страница 12: ...installation or use of products Product Suitability Many jurisdictions have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary f...

Отзывы: