WMC-2500
Model No.
Power Supply Ph-V-Hz
Cooling Capac-
ity Btu/h
Power Consump-
on Wa s
Rated Cur-
rent Amps
EER Btu/
Wh
WMC-2500
Single Phase, 115V, 60Hz
10,000
1000
10
10.0
Model No.
Nema Plug
Power Cord
Gauge AWG
Power Cord Length
Dimensions
W x D x H - in. (mm)
WMC-2500
5-15P
14
10
17.25 x 24 x 20
(438 x 610 x 508)
Model No.
Weight (Net / Gross) Lbs(kg)
No. of Cool Air
Outlets Pcs
Condensate tank
Gallons(Liters)
Ambient temperature
range °F( °C)
WMC-2500
121 / 128 (54 / 58)
1
Auto Pump
Included
64~113 (18~45)
Model No.
Se ng temperature
(Room cool mode) °F( °C)
Se ng temperature
(Spot cool mode) °F( °C)
WMC-2500
64~86 (18~30)
32~86 (0~30)
Model No.
Applica on Area
(Room cool mode) ²(m²)
Refrigerant
Type / oz(g)
Design Pressure - Hi/
Low Psig
WMC-2500
258 (24)
16 (440)
465 / 250
Model No.
Indoor Air Flow
(High/Low)CFM(CMM)
Wheels
pcs / diameter
Hot Air Duct Diam-
eter In.(mm)
Maximum Duct Length
(m)
WMC-2500
320 / 220 (9.1 / 6.2)
4 / 76.2mm
6 (150)
10 (3)
Safety Devices
Compressor overload protector, An -freezing thermister,
Automa c restart (Power interrup on), Compressor me
delay program, High pressure switch
Features
Temperature control, Self-diagnos c func on, Two speed
fan, Washable
fi
lters, °F( °C) display, O
ff
- mer, Drain pump
is included, Humiaity control.
General Safety Informa
Ɵ
on
Please read this manual carefully for instruc ons on correct installa on and usage. Please read
all safeguards,
1. Transport and store the unit in and upright posi on only. Leave unit in an upright posi on for
at least 3 hours before
fi
rst use.
2. Always place the unit on an even, level surface.
3. Ensure the unit is connected to a grounded power supply of the correct ra ng / capacity.
4. The unit will cool when the room temperature is between 18
˚
C (64.4
˚
F) ~ 45
˚
C (113
˚
F) de-
pending on the thermostat se ng.
5. DO NOT use this unit for func ons other than those described in this instruc on manual.
6. DO NOT lt the unit.
Speci
fi
ca
Ɵ
ons